7 Functional check
7.1 Functional check
The indication LEDs on the Sensor and the display of the Manager IQ Easy display information
on the status of the Sensor.
Table 1, overview status indication Display Manager IQ Easy and Sensor IQ Easy
Display indication
Manager IQ Easy
LED indication Sensor
Status
Sensor
Green
Green flashing 1 Hz
Standby
Blue
Green on
Operating, no alarm, no warning.
Orange
Orange
1 active segment shows a value exceeding the
warning setting
Red
Red on
1 active segment shows a value exceeding the
alarm setting
Grey / no connection
Red flashing 5 Hz
No communication (IQ)
7.2 Functional check via the Manager IQ Easy
The display of the Manager IQ Easy displays information on the status of the anti-static bar.
Both on the main screen and on the device screens, the status of the bar can be viewed by
means of the background colour behind the icon
:
Green = standby, blue = running OK, orange = warning, red = alarm.
Detailed information is provided on the
Information, Graphics, Action log
and
Data log
Tab.
7.2.1 Information tab
Using the
buttons you can scroll through the various pages.
Information regarding operation that can be found here:
-
Last warning
: displays the date and time from the moment the warning set point was last
exceeded (during delay time at the least)
-
Last warning
: displays the date and time from the moment the alarm set point was last
exceeded (during delay time at the least)
-
Web voltage average (all) [kV]:
this will display the actual average value of all active
segments.
-
Web voltage peak (all) [kV]:
this will display the maximum negative and positive peak value
of all active segments (during the last
logfile refresh time
).
Every time the logfile is written, this value will be reset to 0.
-
Web voltage seg x [kV]:
this will display the actual value of segment x.
-
Web voltage peak seg x [kV]:
here, the maximum negative and positive peak value of
segment x will be displayed (during the last
logfile refresh time
).
Every time the logfile is written, this value will be reset to 0.
- If another device, e.g. a Performax Easy IQ, is connected to the Sensor, this additional
device will be displayed under
Paired device
.
-
Last Calibration date seg x.
The date the segment has last been calibrated at Simco-Ion