![Simco Sensor IQ Easy User Manual Download Page 59](http://html1.mh-extra.com/html/simco/sensor-iq-easy/sensor-iq-easy_user-manual_1274738059.webp)
SensorIQEasy_UM_9752023110_NL_D_GB_V2_0
58
6.9 (De)activating active segments (expert mode)
If desired, sensor segments can be activated or deactivated.
The sensor segments present are set to active by default so that they all contribute to the
calculation of the average values.
If a segment is no longer in front of the object or film to be measured, this segment has to be
deactivated, as the average value calculation will be incorrect otherwise.
- [
(n)x
“Active segments”
By clicking the segment in question it will be deselected or selected, consecutively. Choose
from the segments and confirm with
]
The segments are numbered from the side of the M12 connector.
6.10 (De)activating Datalogging (expert mode)
If desired, the manager can log measurement values and data regarding the operation of the
bar.
To (de)activate this data logging, the parameter
Data logging
has to be changed.
For detailed information on datalogging, please refer to the manual of the Manager IQ Easy.
- [
(n)x
“
Data logging
”
select
On
or
Off
]
6.11 Switching bar on/off remotely through the remote on/off input on the manager or
using fieldbus (expert mode) (will be implemented in the software later)
If desired, the manager can be switched on and off using the remote on/off input of the Manager
or by means of an instruction of the optional Fieldbus.
With this, one machine control can switch several selected devices, including this bar, on/off at
the same time without having the operator to perform actions for this.
For selecting this, the
Remote on/off source
parameter has to be changed from
Continuous
to
Remote
or
Fieldbus.
- [
(n)x
“
Remote on/off source
”
select
Remote
or
Fieldbus
]
6.12 (Un)coupling Sensor from/to another device (expert mode)
If the sensor data is used by other devices, the coupling will be displayed if it has already been
coupled on the other device, so that the operator can see another device is coupled and any
changes will directly influence the coupled device(s).
This can be erased if not desired.
- Select the information page with the parameters to be changed by:
- [
(n)x
“
Paired device”
select ”
none
”