Troubleshooting
6.1
Shunt Sensors not visible
If PICO is showing a wrong sign for current value, then check if the shunt is
correctly installed. This means that the consumers/generators minus
(optionally plus) terminal is connected to the IN terminal on the shunt.
If this is not the case, try to reinstall the shunt or simply switch the IN and
OUT terminal via the shunt configuration on PICO.
6.2
Shunt/tank sensor is not visible on PICO
If the shunt/tank sensor is not visible in PICO’s menu, check the following:
·
Is the SCQ25T properly connected via the SiCOM port to the PICO.
·
If you are using your own SiCOM cable make sure it has the right square
and is twisted.
6.3
Tank sensor is showing an empty tank
In case you installed the sensor for the first time, consider checking the
following:
·
Check if the tank sensor is covering the whole tank level.
·
If you are using a floating sensor, which is too short, it can happen that the
sensor is not detecting any liquid under a specific level.
·
Consider recalibrating the tank sensor.
Summary of Contents for SCQ25T
Page 1: ...S I M A R I N E SCQ25T Digital Shunt and Tank Module USER MANUAL V2 0 EN USER MANUAL ...
Page 4: ......
Page 5: ...Introduction 1 ...
Page 7: ...Safety 2 ...
Page 9: ...Overview 3 ...
Page 11: ...Installation 4 ...
Page 14: ......
Page 15: ...Technical specifications 5 ...
Page 17: ...Troubleshooting 6 ...
Page 19: ...Safe Voyage SIMARINE marine electronics www simarine net 2022 All rights reserved ...