Figure 43: The ramp-soak-spike reflow profile of SIM5360
For details about secondary SMT, please refer to
document [26].
6.3
Moisture Sensitivity Level (MSL)
SIM5360 is qualified to Moisture Sensitivity Level (MSL) 5 in accordance with JEDEC J-STD-033. The
module should be mounted within 48 hours after unpacking in the environmental conditions of
temperature <30°C and relative humidity of <60% (RH). It is necessary to bake the module if the above
conditions are not met:
Table 47: Moisture sensitivity level and floor life
Moisture Sensitivity Level
(MSL)
Floor Life (out of bag) at factory ambient
≤
30
°
C/60% RH or as
stated
1
Unlimited at
≦
30
℃
/85% RH
2
1 year
2a
4 weeks
3
168 hours
4
72 hours
5
48 hours
5a
24 hours
6
Mandatory bake before use. After bake, it must be reflowed within the
time limit specified on the label.
NOTE:
For product handling, storage, processing, IPC / JEDEC J-STD-033 must be followed.
SIMCOM
CONFIDENTIAL