Page 1: ...lies Compact design with a depth of 140mm for easy integration 80 PLUS Gold certification 100 modular cables 24 7 continuous power output with 40 operating temperature Class leading single 12V rail St...

Page 2: ...ding or performing maintenance on your system A copy of this manual can also be downloaded from our website at Installation and system optimization guide General Input Characteristics Output character...

Page 3: ...pply This specification also defines worldwide safety and electromagnetic compatibility requirements for the power supply which is intended for use in computer products 1 General 2 1 Input Voltage Nom...

Page 4: ...all be less than the ratings of its critical components including input fuse bulk rectifiers and surge limiting device 2 5 Efficiency ST75F GS ST65F G ST55F G provides an efficiency of 87 minimum when...

Page 5: ...loscope The output terminal shall add a tantalum capacitor of 10uF in parallel with a ceramic capacitor of 0 1uF ST65F G Output Voltage 5V 12V 12V 5Vs 3 3V Load MIN 0 0A 0 0A 0 0A 0 0A 0 0A Range MAX...

Page 6: ...uts except the 5VSB turn off This signal is pulled to a standby voltage by a pull up resistor internal to the power supply TTL level H 2 0 V 5 25 V L 0 0 V 1 0 V Load Light Load Typical Load Full Load...

Page 7: ...e the under voltage thresholds of the power supply When this signal is asserted high there should be sufficient mains energy stored by the converter to guarantee continuous power operation within spec...

Page 8: ...wer delivery since short circuit of any output or over total power at high line 4 2 4 Short Circuit Protection Short circuit placed on 5V 12V 3 3V 12V will latch off 5VSB will auto recovery 4 2 5 Over...

Page 9: ...ge in 0 C environment The power supply can operate normally at any altitude between 0 to 10000 feet 5 2 Cold Start 5 Start Stability 6 1 1 Operating 6 1 Temperature and Humidity 6 2 Altitude Sweep and...

Page 10: ...lied between both primary and secondary windings for a minimum of one minute 8 4 Dielectric Voltage Withstand 8 Product Safety A TTL compatible signal for the purpose of initiating an orderly start up...

Page 11: ...ed The MTBF of the power should be 100 000 hours min 10 MTBF Applying 220Vac for 230V model 11 1 Input Voltage Applying 75 loads for the power supply in 45 5 oC chamber for 4 hours 11 2 Test Condition...

Page 12: ...NO G1122...