Before You Begin

 

‰

Check your packing slip to 
verify that you have all the 
necessary items. 

 

‰

If your EdgeConnect model 
requires it, ensure that you 
have the associated rack mount 
instructions.  

 

‰

Make sure you have a standard 
Phillips screwdriver.

 

‰

Supply circuits should be 
protected by a minimum 15A, 
maximum 20A circuit breaker.

 

‰

On the network equipment, 
identify the 10/100/1000 
Ethernet ports and/or the 
1Gbps/10Gbps fiber ports.

1

  Rack Mount the Appliance

Based on your model, refer to the separate instructions for rack mount, 
desk mount, or wall mount.

2

  Install the Appliance into the Network

a.  Identify the relevant ports on the rear of the appliance.

b.  Connect the supplied network cables from the appliance to the 

identified network equipment ports.

c.   

DO NOT connect the power cables yet

All copper RJ-45 Gigabit Ethernet interfaces in the Silver Peak appliance 
support MDI/MDI-X and auto-negotiation.  

The fiber interfaces support: 
•  LC connectors
•  multi-mode 50

µ

 fiber / 62.5

µ

 fiber

3

    Connect Power Cords 

Depending on the model, your appliance may have a single power supply, 
or redundant power supplies. 

a.  Connect each power cable to the Silver Peak appliance and to your 

local power source. 

b.  For redundancy, plug in 

all

 power cords, preferably to different 

power sources.

4

  Turn the Power On

Some appliances power up as soon as they’re plugged in, others don’t. If 
the power is off, turn it on. If you don’t plug in all the power cords, an 
audible alarm sounds until you do.

a.  Verify that each power supply’s LED illuminates green.

b.  On the front panel, verify that the 

Power

 LED illuminates green or 

blue.

5

  

Optionally

, connect the management ports 

It is not necessary, however, if you want to create local, physical access to 
the management ports, you can do so as follows: 

Silver Peak assigns the 

MGMT1

 ethernet interface a default IP address of 

169.254.0.1

 and a subnet mask of 

/16

 (the same as 

255.255.0.0

).

Both RJ-45 Gigabit Ethernet interfaces (

MGMT0

 and 

MGMT1

) support 

MDI/MDI-X and auto-negotiation. 

a.  Identify the appliance’s 

MGMT0

 and 

MGMT1

 interfaces.

b.  Using the 

blue

 straight-through cable, connect the appliance’s 

MGMT0

 interface to the network equipment interface.

c.  Using the 

red

 crossover cable, connect the appliance’s 

MGMT1

 

interface to your PC.

You’ve now completed the physical installation and are ready to register 
the product with Unity Orchestrator. 