Silicon Laboratories Si890x-PWR-EVB User Manual Download Page 1

Rev. 1.1 10/12

Copyright © 2012 by Silicon Laboratories

Si890x-PWR-EVB

S i 8 9 0 x - P W R - E V B

S i 8 9 0

X

  D

I G I TA L

  I

S O L A T O R

- B

A S E D

,   1 0 - B

I T

  I

S O L A T E D

 

M

O N I T O R I N G

  A D C   U

S E R

S

  G

U I D E

1.  Introduction

The Si890x are isolated ADCs suitable for low-frequency analog data acquisition applications. These devices
integrate an isolated 10-bit SAR ADC with I

2

C, UART, or SPI serial communication ports. Isolation ratings of 2.5 or

5 kV are available. See the Si8900 data sheet for details.

2.  Kit Contents

The Si890xPWR-EVB Evaluation kit contains the following items:

Si890xPWR-EVB evaluation module containing:



High voltage 110 V/220 V ac line current and voltage measurement circuit with 3.3 Vpp analog output signals



Si8900 Isolated 10-bit ADC with UART serial port



Si8901 Isolated 10-bit ADC with I

2

C serial port 



Si8902 Isolated 10-bit ADC with SPI serial port 



C8051F007 mixed-signal MCU master controller



AC line-side bias supply

2.1.  Hardware Overview

The Si890xPWR-EVB (Figure 1) demonstrates 50/60 Hz ac line voltage and current measurements. This EVB is
housed in a plastic case with recessed connectors to protect against user electrical shock. The Si890x accepts a
110 or 220 Vac input and supports load currents up to 10 A (max). The on-board line side circuit interface
measures ac voltage and current, which is then digitized by the Si890x on-chip 10-bit ADC. The resulting converted
data is then transmitted through the output side isolated serial port to the on-board master processor (C8051F007
MCU). The C8051F007 converts the serial data back to analog format where it is available to the user at the low-
voltage side of the evaluation module. 

 Key features for this EVB include the following:

EVB module measures ac line voltage (110 Vac or 220 Vac at 50/60 Hz) and ac line current (10 A max)

10-bit ADC with three input channels and selectable, isolated serial ports: UART (Si8900) or I

2

C (Si8901) or SPI 

(Si8902)

High common mode transient immunity (CMTI): 35 kV/µs (min), 50 kV/µs (typ)

Industrial temperature operating range (–40 to +85

°

C)

60-year isolation barrier life at rated working voltage

Safety certified (pending)



CSA component notice 5A approval



IEC 60950, 61010, 60601



VDE/IEC 60747-5-2



UL1577 recognized: (Up to 5 kVrms for 1 minute)

Danger! High Voltage: Read instructions carefully. Do not operate this evaluation board unless it is
housed in its plastic case and secured by the four screws.

Summary of Contents for Si890x-PWR-EVB

Page 1: ...o protect against user electrical shock The Si890x accepts a 110 or 220 Vac input and supports load currents up to 10 A max The on board line side circuit interface measures ac voltage and current which is then digitized by the Si890x on chip 10 bit ADC The resulting converted data is then transmitted through the output side isolated serial port to the on board master processor C8051F007 MCU The C...

Page 2: ...om side of board is recessed to provide an extra margin of space between the housing exterior and the ac line connection Safety Warning The board MUST remain in the plastic enclosure whenever the ac line voltage is connected to the Si890x input terminals C8051F007 Debug Connector AC HV Interface Isolation Barrier C8051F007 MCU Output Connector Jumper Selection Options Si890xPWR EVB Topside Attenua...

Page 3: ...ivers Minimum two channel oscilloscope 22 gauge stranded wire for low voltage signal connector P1 A suitable ac load e g power resistor lamp with or without dimmer max current of 10 A AC line cord wire Note wire gauge depends on the amount of current to be measured Optional line side external dc supply input Use only if the EVB is connected to a low voltage 5 V or less line side device instead of ...

Page 4: ...U RESET input No Jumper Adding a jumper disables master MCU customer master uses serial ports J7 Output connector P1 pin D0 assignments 1 2 Si8900 UART Rx input assigned to P1 pin D0 J8 Output connector P1 pin D1 assignments 1 2 Si8900 UART Tx output assigned to P1 pin D1 J11 110 Vac or 220 Vac line voltage select No Jumper 110 Vac line voltage selected J12 3 3 V bias voltage 1 2 3 3 V bias voltag...

Page 5: ...0 Connects ac line voltage signal to U4 AIN0 J5 Connects external AIN2 to U5 AIN2 Connects external AIN2 to U3 AIN2 Connects external AIN2 to U4 AIN2 J6 Holds master MCU in reset N A N A J7 Connects UART Rx to D0 output header Connects I2 C port SCL to D0 out put header Connects SPI port SD0 to D0 out put header J8 Connects UART Tx to D1 output header Connects I2 C port SDA to D1 out put header Co...

Page 6: ...ise skip to paragraph 4 3 Configuring an Isolated ADC a Choose the isolated ADC to be enabled Note that only one ADC can be in service at a time b Headers J2 J3 and J4 route the ac line side VDD AIN0 and AIN1 corresponding pins of the desired Si890x device Input AIN0 typically measures line input voltage and AIN1 typically measures ac line current For example if the Si8902 is the device to be used...

Page 7: ...ugh the enclosure opening and into the AC_H terminal block opening Be sure there is no bare wire exposed Tighten the screw on the terminal block to secure the AC_H wire Repeat this procedure for the GNDA wire connection to TB1 5 Locate the ac output load terminals AC_OUT and AC_H on TB1 as shown in Figure 6 With the ac line disconnected from the outlet loosen the screws on TB1 corresponding to AC_...

Page 8: ... one end of each wire to each wire to the male connector When soldering is complete plug the male connector into P1 9 Obtain an external adjustable power supply bench or lab supply but do not connect it to the Si890x EVB yet With no load attached turn the power supply on and set the output to 3 3 V Turn the power supply off and discharge its outputs by shorting the positive and negative terminals ...

Page 9: ...tage blue and current yellow waveforms will appear on the oscilloscope as shown in Figure 8 Vary the load to observe the changes in current 13 To power the EVB down first unplug the ac line connection then turn the external dc power supply off Figure 8 AC Voltage Blue and Current Yellow Waveform from Analog Output of the Master Controller C8051F007 as Displayed on the Oscilloscope ...

Page 10: ...OG 100 PF GNDA AN2 J5 J4 J3 J2 C13 X7R 1 0 UF GNDA 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 VDDA NC VREF AIN0 AIN1 AIN2 GNDA RST GNDB VDDB EN SDI SCLK SDO NC VDDB R39 2K SDO SCLK SDI C14 X7R 1 0 UF GNDB VDDB U5 SI8902AD AD0 GS EN 16 15 14 13 12 11 10 9 VDDA AIN0 AIN1 AIN2 GNDA VREF GNDB VDDB SDA SCL NC NC VDDB U4 SI8901AD AD0 GS NC 1 2 3 4 5 6 7 8 RST RSDA R36 R26 2K 4 99K SCL SDA VDDB C12 X7R 1 0 U...

Page 11: ...ND DGND P0 3 P0 2 P0 1 VDD VDD P0 0 SD0 SCLK SCL SDA 17 18 19 20 21 22 23 24 9 10 11 12 13 14 15 16 AV XTAL1 XTAL2 RST TMS TCK TDI TDO 31 30 29 28 27 26 25 32 DAC0 DAC1 TX RX SDI VDDB DAC0 DAC1 AGND AV P0 7 P0 6 P0 5 P0 4 GNDB GNDB VDDB R31 4 75 k R32 4 75 k VDDB VDDB VDDB VDDB VDDB GNDB R33 2 k GNDB 8 10 6 4 2 7 9 5 3 1 HDR2X5 SHROUDED VDDB J1 DEBUG R29 4 75 k Y1 24 576 MHz C19 X5R 33 pF C20 COG ...

Page 12: ...S 5 2 C22 C25 445 1437 1 ND CAP 100 µF X5R CERAMIC 1210 6 3 V 20 or EQ RoHS 6 1 C23 445 4536 1 ND CAP 10 µF X7S CERAMIC 1210 100 V 10 RoHS 7 1 C24 PCC122BNCT ND CAP CERAMIC 1200 pF X7R 0805 50 V 10 or EQ RoHS 8 2 C19 20 PCC330CGCT ND CAP 33 pF NPO CERM 0805 50 V 5 or EQ RoHS 9 1 C17 PCC2318CT ND CAP 4 7 µF X5R CERAMIC 0603 6 3 V 20 or EQ RoHS 10 4 C1 4 445 5211 1 ND CAP 4 7 µF X7S CERAMIC 1812 100...

Page 13: ...S 20 3 R15 17 985 1197 1 ND RES 0 01 1 0 W 2010 1 SMD or EQ RoHS 21 2 R14 R24 P100ACT ND RES 100 SMT 0805 1 8W 5 or EQ RoHS 22 4 R30 34 36 P100KACT ND RES 100 k SMT 0805 1 8W 5 or EQ RoHS 23 5 R1 5 541 100KUCT ND RES 100 k SMT 1206 1 2W 1 or EQ RoHS 24 5 R11 12 21 22 40 P10 0KCCT ND RES 10 0 k SMT 0805 1 8W 1 or EQ RoHS 25 7 R18 19 28 33 37 39 311 2 0kARCT ND RES 2 k SMT 0805 1 8W 5 or EQ RoHS 26 ...

Page 14: ... TIN OR EQ RoHS INSERT AFTER TEST 33 1 U3 Si8900AD A00 GS Silicon Labs IC ISOLATED MONITORING ADC RoHS 34 1 U4 Si8901AD A00 GS Silicon Labs IC ISOLATED MONITORING ADC RoHS 35 1 U5 Si8902AD A00 GS Silicon Labs IC ISOLATED MONITORING ADC RoHS 36 1 U2 TC10143 3VCT713CT ND IC CMOS LDO 3 3 V 50 MA SOT23 5 RoHS 37 9 TP1 9 NO POP TEST POINT WIRE WRAP VIA OR EQ RoHS 38 1 TB1 277 1251 ND TERM BLOCK 5 08 mm...

Page 15: ...to 85 C Si8901D A01 GS I2C SMBus WB SOIC 5 0 kV 40 to 85 C Si8902B A01 GS SPI Port WB SOIC 2 5 kV 40 to 85 C Si8902D A01 GS SPI Port WB SOIC 5 0 kV 40 to 85 C Notes 1 Add an R suffix to the part number to specify the tape and reel option Example Si8900AB A ISR 2 All packages are RoHS compliant 3 Moisture sensitivity level is MSL3 for wide body SOIC 16 package with peak reflow temperatures of 260 C...

Page 16: ...Si890x PWR EVB 16 Rev 1 1 DOCUMENT CHANGE LIST Revision 1 0 to Revision 1 1 Updated Figure 7 on page 8 ...

Page 17: ...Si890x PWR EVB Rev 1 1 17 NOTES ...

Page 18: ...t System is any product or system intended to support or sustain life and or health which if it fails can be reasonably expected to result in significant personal injury or death Silicon Laboratories products are generally not intended for military applications Silicon Laboratories products shall under no circumstances be used in weapons of mass destruction including but not limited to nuclear bio...

Reviews: