S i 8 4 1 0 / 2 0 / 2 1 ( 5 k V )
S i 8 4 2 2 / 2 3 ( 2 . 5 & 5 k V )
16
Rev. 1.1
Table 5. Recommended Operating Conditions
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Ambient Operating Temperature*
T
A
150 Mbps, 15 pF, 5 V
–40
25
125
C°
Supply Voltage
V
DD1
2.70
—
5.5
V
V
DD2
2.70
—
5.5
V
*Note:
The maximum ambient temperature is dependent upon data frequency, output loading, the number of operating
channels, and supply voltage.
Table 6. Regulatory Information*
CSA
The Si84xx is certified under CSA Component Acceptance Notice 5A. For more details, see File 232873.
61010-1: Up to 600 V
RMS
reinforced insulation working voltage; up to 600 V
RMS
basic insulation working voltage.
60950-1: Up to 600 V
RMS
reinforced insulation working voltage; up to 1000 V
RMS
basic insulation working volt-
age.
60601-1: Up to 125 V
RMS
reinforced insulation working voltage; up to 380 V
RMS
basic insulation working voltage.
VDE
The Si84xx is
certified according to IEC 60747-5-2. For more details, see File 5006301-4880-0001.
60747-5-2: Up to 891 V
peak
for basic insulation working voltage.
60950-1: Up to 600 V
RMS
reinforced insulation working voltage; up to 1000 V
RMS
basic insulation working volt-
age.
UL
The Si84xx is certified under UL1577 component recognition program. For more details, see File E257455.
Rated up to 5000 V
RMS
isolation voltage for basic insulation.
*Note:
Regulatory Certifications apply to 2.5 kV
RMS
rated devices which are production tested to 3.0 kV
RMS
for 1 sec.
Regulatory Certifications apply to 5.0 kV
RMS
rated devices which are production tested to 6.0 kV
RMS
for 1 sec.
For more information, see "6. Ordering Guide" on page 29.