AN625
Rev. 0.1
41
3.2.20. RX_HOP
Summary: Fast RX hopping
Purpose:RX Hop is designed to provide the fastest RX to RX switching time for frequency hopping systems.
The RX to RX time is 75usec using this command. The VCO_CNT must be calculated offline and stored in the
host.
Command Stream
Reply Stream
Parameters:
INTE[7:0] - INTE register value
FRAC2[7:0] - FRAC2 register value
FRAC1[7:0] - FRAC1 register value
FRAC0[7:0] - FRAC0 register value
VCO_CNT0[7:0] - VCO_CNT0 register value
Response:
None
RX_HOP Command
7
6
5
4
3
2
1
0
CMD
0x36
INTE
INTE[7:0]
FRAC2
FRAC2[7:0]
FRAC1
FRAC1[7:0]
FRAC0
FRAC0[7:0]
VCO_CNT1
00000000
VCO_CNT0
VCO_CNT0[7:0]
RX_HOP Reply
7
6
5
4
3
2
1
0
CMD_COMPLETE
CTS[7:0]
Summary of Contents for Si446 Series