AN625
Rev. 0.1
11
3.2.3. FUNC_INFO
Summary:
Returns the Function revision information of the device.
Purpose:
Return Function revision numbers for currently loaded functional mode firmware. Contrast with PART_INFO
Command Stream
Reply Stream
Parameters:
None
Response:
REVEXT[7:0] - External revision number
Range: 0 to 255
REVBRANCH[7:0] - Branch revision number
Range: 0 to 255
REVINT[7:0] - Internal revision number
Range: 0 to 255
PATCH[15:0]
ID of applied patch. This is also the last 2 bytes in the associated patch file (*.csg).
0x0000 = No patch applied.
FUNC[7:0] - Current functional mode
1 = Tranceiver
2 = Receive only
3 = Transmit only
FUNC_INFO Command
7
6
5
4
3
2
1
0
CMD
0x10
FUNC_INFO Reply
7
6
5
4
3
2
1
0
CMD_COMPLETE
CTS[7:0]
REVEXT
REVEXT[7:0]
REVBRANCH
REVBRANCH[7:0]
REVINT
REVINT[7:0]
PATCH
PATCH[15:8]
PATCH
PATCH[7:0]
FUNC
FUNC[7:0]
Summary of Contents for Si446 Series