![Silicon Laboratories EFR32xG14 Wireless Gecko Reference Manual Download Page 520](http://html1.mh-extra.com/html/silicon-laboratories/efr32xg14-wireless-gecko/efr32xg14-wireless-gecko_reference-manual_1271728520.webp)
Bit
Name
Reset
Access Description
8
MSTOP
0
(R)W1
Clear MSTOP Interrupt Flag
Write 1 to clear the MSTOP interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
7
NACK
0
(R)W1
Clear NACK Interrupt Flag
Write 1 to clear the NACK interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
6
ACK
0
(R)W1
Clear ACK Interrupt Flag
Write 1 to clear the ACK interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags (This
feature must be enabled globally in MSC.).
5:4
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
3
TXC
0
(R)W1
Clear TXC Interrupt Flag
Write 1 to clear the TXC interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags (This
feature must be enabled globally in MSC.).
2
ADDR
0
(R)W1
Clear ADDR Interrupt Flag
Write 1 to clear the ADDR interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
1
RSTART
0
(R)W1
Clear RSTART Interrupt Flag
Write 1 to clear the RSTART interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
0
START
0
(R)W1
Clear START Interrupt Flag
Write 1 to clear the START interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags