Using the 1U Console Option
007-6399-002
17
Using the 1U Console Option
The SGI optional 1U console is a rackmountable unit that includes a built-in keyboard/touchpad,
and uses a 17-inch (43-cm) LCD flat panel display of up to 1280 x 1024 pixels. The 1U console
attaches to the administrative controller server using USB and HD15M connectors or to an
optional KVM switch (not provided by SGI). The 1U console is basically a “dumb” VGA
terminal, it cannot be used as a workstation or loaded with any system administration program.
Note:
While the 1U console is normally plugged into the administrative controller server in the
SGI ICE XA system, it can also be connected to a rack leader controller server in the system for
terminal access purposes.
The 27-pound (12.27-kg) console automatically goes into sleep mode when the cover is closed.
Levels of System and Chassis Control
The chassis management control network configuration of your ICE XA series machine will
depend on the size of the system and the control options selected. Typically, any system with
multiple blade enclosures will be interconnected by the chassis managers in each blade enclosure.
Note:
Mass storage option enclosures are not monitored by the blade enclosure’s CMCs.
Chassis Controller Interaction
In all SGI ICE XA series systems the system chassis management controllers communicate in the
following ways:
•
All blade enclosures within a system are polled for and provide information to the
administrative node and RLC through their chassis management controllers (CMCs). Note
that the CMCs are enlarged for clarity in Figure 2-2 on page 18.
•
The CMC does the environmental management for each blade enclosure, as well as power
control, and provides an Ethernet network infrastructure for the management of the system.
For an overview of how all the primary system components interact within the Ethernet
network infrastructure, see the section “System Hierarchy” in Chapter 5.
Summary of Contents for ICE XA
Page 1: ...SGI ICE XA System Hardware User Guide Document Number 007 6399 002 ...
Page 4: ......
Page 12: ......
Page 25: ...Powering the System On and Off 007 6399 002 7 Figure 1 4 Three Phase PDU Example ...
Page 32: ......
Page 65: ...SGI ICE XA Series D Rack 42U 007 6399 002 47 Figure 4 1 D Rack Front Lock Example ...
Page 72: ...54 007 6399 002 4 Rack Information Figure 4 4 E Cell Rack Assembly Example CDU on Left ...
Page 82: ......