Silent Alert MM4A-2212-EU Quick Start Manual Download Page 1

PUSH

Status light

Test button

Configuration 

switch Cover

PP3 battery 

contacts

Screw cap

Screw cap

CCD4A-2220-EU 

CARE CALL 

MINI MAGNETIC
DOOR MONITOR

USE ALKALINE PP3 
9 V BATTERY ONLY

Batch 06/01/14 

www.silentalert.ie 

Silent Alert International, IRL 

Tel: +353 (0)1 247 9007

  Keys 1-4 System 

Channel

  Key 5=10 Sec Delay
  Key 6=20 Sec Delay

Keys 5+6=30 Sec Delay

  Key 7 Leave ON  

Key 8 Not Used

USE WITH MAGNET SUPPLIED

PP3 Battery

PUSH

PUSH

The light will then flash green 

several times to show the 

battery voltage. 

9 flashes = 9Volts in the battery. 

When a battery is first fitted the 

indicator light will flash red then 

green a few times.  

1.

Install a 9 volt PP3 alkaline or lithium battery 

making sure to observe the correct polarity.

PUSH

If the light flashes red at this 

point the battery is flat  

and will need to be replaced. 

To repeat the battery check remove the battery, press the test 

button then re-insert the battery to start the sequence again.

TD4A

 MONITOR

USE ALKALINE PP3 
9 V BATTERY ONLY

Batch 06/01/14 

www.silentalert.ie 

Silent Alert International, IRL 

Tel: +353 (0)1 247 9007

  Keys 1-4 System 

Channel

  Key 5=10 Sec Delay
  Key 6=20 Sec Delay

Keys 5+6=30 Sec Delay

  Key 7 Leave ON  

Key 8 Not Used

USE WITH MAGNET SUPPLIED

PUSH

1 2 3 4 5 6 7 8

Configuration switches shown 

with cover removed. Do not alter 
these without referring to page 2

Input 

terminals

2.

Remove the screw caps 

& Secure the monitor to 

the door frame or 

adjacent wall using he 

screws provided.

Press the test button and 

check the Pager and/or 

SignWave receive 

the signal. 

1

3

If a bell push is connected to a chime 

this may be replaced using the 

mini monitor.

PUSH

1.

1 2 3 4 5 6 7 8

Move control key 8 to the right. 

Insert the wires from the door 

chime into terminals 1 & 3 on the 
monitor securing with the locking 

screws. 

2.

3.

The monitor will 

now trigger the 

door chime and 

send a signal to 

the Pager or 

SignWave each 

time the button 

is pressed.  

A voltage applied across terminals 1 & 2 

will also trigger the unit. Both AC and DC 

voltages from 5 - 30 Volts will activate 

the unit.

1

2

NOTE:

 If a DC voltage is 

applied the positive 

needs to be connected to 

terminal 2 and negative 

to terminal 1. 

(5 - 30V AC/DC)

Voltage triggering 

Standard operation

Short circuit trigger / bell push replacement

3.

If the mini monitor is to be 

used outside a 

StormGuard cover 

is available.

This clear cover simply 

fits around the monitor 

and protects it 

from moisture. 

WARNING

DO NOT 

apply mains power or any 

voltage in excess of 30 Volts as 

damage will result.

Only suitably qualified persons 

should attempt to link this unit into 

systems or equipment other than a 

low voltage door chime 

Wiring example

When wiring across a coil or similar, 

Common (negative) 

to terminal one

Make sure the common 

(negative) wire on the bell 

push is connected to terminal 

1 to avoid false triggering. 

Any questions? Call us on

+353 (0)1 247 9007