4.2 Electrical Installation
Destruction of parts of equipment and loss of regulation control
`
All lines for connecting the absolute encoder must be shielded.
`
Never wire or disconnect electrical connections while they are live.
`
Perform wiring work in the de-energized state only.
`
Use strands with suitable ferrules.
`
Check all lines and plug connections before switching on the device.
`
Switch on operating voltage together with the downstream electronic
unit (e. g., control unit).
Basically, all connections are protected against external interference.
Choose a place of operation that excludes inductive or capacitive inter-
ference influences on the absolute encoder. When mounting the system-
keep a maximum possible distance from lines loaded with interference. If
necessary, provide additional installations including screening shields or
metallized housings.
Admissible power input
Supply for the absolute encoder shall be sized sufficiently. The voltage val-
ues are a function of the device design and can be referred to in the tech-
nical data in chapter
.
Pin configuration of the potentiometer without transducer
Pin
Designation
1
Po1
2
Po2
3
S2
4
Pe2
5
nc
6
Pe1
7
S1
8
nc