background image

323/17

MSK320

Magnetsensor

Originalmontageanleitung 

Deutsch

 Seite 

2

Magnetic sensor

Translation of the Original Installation Instructions 

English

 page 

19

Summary of Contents for MSK320

Page 1: ...323 17 MSK320 Magnetsensor Originalmontageanleitung Deutsch Seite 2 Magnetic sensor Translation of the Original Installation Instructions English page 19...

Page 2: ...und Hinweisen 3 2 3 Zielgruppe 4 2 4 Grundlegende Sicherheitshinweise 4 3 Identifikation 5 4 Installation 5 4 1 Mechanische Montage 5 4 2 Montage Magnetband 6 4 3 Montage Magnetsensor 8 4 4 Montage Ma...

Page 3: ...im Industriebereich vorgesehen die keinen besonderen elektrischen oder mechanischen Sicherheitsanforderungen unterliegen 1 Beachten Sie alle Sicherheitshinweise in dieser Anleitung 2 Eigenm chtige Um...

Page 4: ...rs und deren Integration in die komplette Maschinenanlage Nicht ausreichend qualifiziertes Personal Personensch den schwere Sch den an Maschine und Magnetsensor wer den durch nicht ausreichend qualifi...

Page 5: ...ntifikation Das Typenschild zeigt den Ger tetyp mit Variantennummer Die Lieferpa piere ordnen jeder Variantennummer eine detaillierte Bestellbezeichnung zu z B MSK320 0023 Varianten Nr Ger te Typ Das...

Page 6: ...hnellreiniger ange boten werden F r eine optimale Verklebung m ssen die Klebefl chen trocken sein und es ist mit h chstm glichem Anpressdruck zu verkleben Verklebungstemperatur zwischen 20 C und 30 C...

Page 7: ...andes gegen Abl sen sichern Abb 1 Montage Magnetband Montagebeispiele Die einfache Montageart durch angeschr gtes Magnetband wie in Abb 2 ist nur in sehr gesch tzter Umgebung zu empfehlen Bei ungesch...

Page 8: ...netsensor Bauform F kann z B an einen Montagewinkel mit ent sprechender Befestigungsbohrung durch Anziehen der zwei Muttern M8x0 5 befestigt werden Anwendung LINEAR MSK320 Bauform ZM mit MB320 1 Abb 6...

Page 9: ...on der Z hlrichtung mit Magnetband und Montage Sensor Magnetband Abstandsma e Toleranzen 3 1 2 3 4 4 Montage Magnetring Magnetring MR320 Nach dem Aufschieben des Magnetrings auf die Welle wird durch A...

Page 10: ...toff UHU Endfest 300 oder hn liches mit der Welle verbunden 1 Um den Rundlauf des Magnetrings MRF320 zu gew hrleisten sollte die Klebefl che als Nut ausgebildet sein Klebstoff darf nicht aus der Nut h...

Page 11: ...4 Freistich an der Vollwelle f r Gewindestift wird empfohlen 5 Metallflansch Abb 10 Definition der Z hlrichtung mit Magnetring und Montage Sensor Magnetring Abstandsma e Toleranzen 4 3 5 1 2 3 MSK320...

Page 12: ...k z B Steue rung einschalten Alle Anschl sse sind prinzipiell gegen u ere St reinfl sse gesch tzt Der Einsatzort ist so zu w hlen dass induktive oder kapazitive St rungen nicht auf den Magnetsensor od...

Page 13: ...braun GND schwarz schwarz A gelb B gr n I R FR violett E8 9 pol Stiftkontakt Buchsenkontakt E6 7 bzw 8 pol Stiftkontakt Buchsenkontakt M16 1 6 10 ber Kabelmantel schieben 2 Kabel abisolieren 3 Schirm...

Page 14: ...8 Pin E6 Pin E8 A 3 3 1 1 B 4 4 2 2 UB 2 2 4 4 GND 1 1 5 5 A 6 6 B 7 7 nc 5 7 5 9 3 3 8 9 Signal nicht invertiert mit Referenzsignal invertiert mit Referenzsignal Pin E6 Pin E8 Pin E6 Pin E8 A 3 3 1 1...

Page 15: ...chlossen Anschlussbelegung Kapitel 4 5 Die Abstandstoleranzen wurde nicht ber die gesamte Messstrecke eingehalten siehe Abb 6 Abb 8 Abb 11 Kabelunterbrechung Abtrennung durch scharfe Kanten Quetschung...

Page 16: ...ichtlinien des jeweiligen Landes m ssen hierzu beachtet werden 8 Zubeh r nicht im Lieferumfang enthalten 8 1 Flexible Referenzmarke Zubeh r SIKO Art Nr 88434 gem Kurzanleitung Art Nr 88556 9 Technisch...

Page 17: ...eitsproportio nale Signalausgabe Anschlussart offenes Kabelende Steckverbinder 7 8 polig D Sub 9 polig Systemdaten Erg nzung Aufl sung 0 04 0 05 0 08 0 1 0 16 0 2 0 8 mm Skalierungsfaktor 1 4 5 8 10 1...

Page 18: ...echnische Daten Deutsch MSK320 Datum 02 11 2017 Art Nr 80353 nd Stand 323 17 18 Umgebungsbedingungen Erg nzung Schockfestigkeit 500 m s2 11 ms EN 60068 2 27 Vibrationsfestigkeit 100 m s2 5 150 Hz EN 6...

Page 19: ...arget group 21 2 4 Basic safety information 21 3 Identification 22 4 Installation 22 4 1 Mechanical mounting 22 4 2 Mounting the magnetic tape 23 4 3 Mounting the magnetic sensor 25 4 4 Mounting the m...

Page 20: ...n industrial applications that are not subject to special electrical or mechanical safety requirements 1 Observe all safety instructions contained herein 2 Arbitrary modifications and changes to this...

Page 21: ...e personal injury serious damage to machinery or magnetic sensor Configuration commissioning mounting and maintenance by trained expert personnel only This personnel must be able to recognize dangers...

Page 22: ...of unit The magnetic tape is identifiable by a consecutive imprint e g MBxxxx GEK WT RP NNNNNN batch number reference point material carrier tape accuracy MB type 4 Installation 4 1 Mechanical mounti...

Page 23: ...l with the mounting surface or distance to be measured Unevenness deteriorates measuring accuracy Length of the magnetic tape For technical reasons the magnetic tape must be 55 mm longer than the dist...

Page 24: ...ed environ ments In a non protected environment there is the danger of peeling off Mounting approaches as shown in Fig 3 and Fig 4 are more suitable in such cases Optimum protection is provided by mou...

Page 25: ...d e g to a mounting square with a corresponding mounting bore by tightening the two nuts M8x0 5 LINEAR application MSK320 design ZM with MB320 1 Fig 6 Definition of the counting direction with magneti...

Page 26: ...ignal A before B 2 Admissible deviation of tape sensor 0 1 2 mm 3 arrow Fig 8 Definition of the counting direction with magnetic tape and assemblage sensor magnetic tape gap measure tolerances 3 1 2 3...

Page 27: ...unning of magnetic ring MRF320 the glueing surface should be keyway like Make sure that the glue is only inside the keyway Apply glue and then immediately fix magnetic ring Please also observe glue ma...

Page 28: ...solid shaft for tread plug is recom mended 5 Metallflange Fig 10 Definition of the counting direction with magnetic ring and assemblage sensor magnetic ring gap measure tolerances 4 3 5 1 2 3 MSK320 d...

Page 29: ...ltage together with downstream electronics e g control unit Basically all connections are protected against external interference Choose a place of operation that excludes inductive or capacitive inte...

Page 30: ...ue UB brown brown GND black black A yellow B green I R FR violet E8 9 pol plug pin socket contact E6 7 or 8 pole plug pin socket contact M16 1 Slip 6 10 over outer cable 2 Strip cable 3 Turn down scre...

Page 31: ...Pin E6 Pin E8 A 3 3 1 1 B 4 4 2 2 UB 2 2 4 4 GND 1 1 5 5 A 6 6 B 7 7 nc 5 7 5 9 3 3 8 9 Signal not inverted with reference signal inverted with reference signal Pin E6 Pin E8 Pin E6 Pin E8 A 3 3 1 1...

Page 32: ...not or incorrectly connected pin assignment see chapter 4 5 The distance tolerances were not observed over the whole measuring length see Fig 6 Fig 8 Fig 11 Cable squeezed interrupted cut by sharp ed...

Page 33: ...it has been taken out of operation ultimately Observe the environment protec tion guidelines of your country 8 Accessory not included in the scope of delivery 8 1 Flexible reference mark Accessory SIK...

Page 34: ...V TTL Jitter 15 0 5 mm reading distance Pulse width of reference signal 1 increment s Real time requirement speed proportional signal output Type of connection open cable end plug connector 7 8 pole D...

Page 35: ...23 17 35 Ambient conditions Additional information EMC EN 61000 6 2 interference resistance immis sion EN 61000 6 4 emitted interference emission Protection category IP67 EN 60529 Shock resistance 500...

Page 36: ...g 2 79256 Buchenbach Telefon Phone 49 7661 394 0 Telefax Fax 49 7661 394 388 E Mail info siko de Internet www siko global com Service support siko de nderungen vorbehalten Subject to technical alterna...

Reviews: