EtherHaul™ 8000 Installation, Operation and Maintenance Manual
Page 29
Figure 2-9 Grounding Scheme
Caution:
Improper electrical grounding can result in excessive electromagnetic interference or
electrical discharge.
This equipment must be permanently earthed for protection and functional
purposes. To make a protective earth connection, use the grounding point located on
the radio using a minimum amount of 16AWG grounding cable or according to local
electrical code.
Siklu will not be held responsible for any malfunction or damage in the event that the
radio is not properly grounded.
2.8.3
Preparing the Cables
Before inserting the cable connector into the radio, you must first enclose the cable
connector in a protective All-Weather shell. Three sets of All-Weather shells are
provided with the radio for the radio interfaces.
The provided protective All-Weather Shells fit cables from 3.5mm to 9.0mm diameter.