10
Technical data
The technical data of customised versions may differ from the data in these instructions.
Please observe the information specified on the type plate.
10.1
Characteristics VO
Type
VO…VA
VO…VP*
1
VO…AP*
1
Characteristics
Measuring range [l/min]
0.03…66
0 •
(
Accuracy*
2
±0.5 % of reading
Repeatability*
2
<0.05 %
Pulse rate / K-factor [1/l]
3100…1.7
• (
Degree of protection
(DIN EN 60529)
IP65
Wetted parts' materials*
3
Housing
Stainless steel
Stainless steel
Aluminium
Oval gear
Stainless steel
PEEK
PEEK
Bearing
Coal
PEEK
PEEK
Axle
Stainless steel
Stainless steel
Stainless steel
O-ring
FKM (Standard
) • optional: EPDM, FEP
Process variables
Medium to measure
Liquids (Group1 according to Pressure Equipment Directive 97/23/EG)
Permissible viscosity*
4
0.3…350 mPa s
0.3…50 mPa s
Max. particle size
25…100 µm
Medium temperature
-1
0…70 °C • (
-10…130 °C with high temperature sensor)
Ambient temperature
-20…70 °C
Storage temperature
10…55 °C
Nominal pressure
PN40
• (
PN25 with FEP gasket)
Process connection
G¼… G2 • (
*1 Not available for VO 50 and VO 115.
*2 Test conditions: Viscosity
>3 mPa s • Medium
temperature 20 °C.
*3 other material combinations on request.
*4 with Newtonian properties