Temperature calibrators
Series TP37 / TP3M
Types: TP 37 200 E • TP 37 165 E • TP 37 166 E
• TP 37 700 E • TP 3M 165 E • TP 3M 255 E.
Operating manual
(Translation)
Operating manual .................................................. page 1 - 60
Page 1: ...ce is resold please provide the operating manual along with it SIKA Ba_TP37 TP3M_en 07 2015 Temperature calibrators Series TP37 TP3M Types TP 37 200 E TP 37 165 E TP 37 166 E TP 37 700 E TP 3M 165 E T...
Page 2: ...ns 14 4 2 Electrical connection 15 4 3 Preparing of the calibrator 16 4 3 1 Dry block calibrator 17 4 3 2 Calibrator for infrared thermometer 18 4 3 3 Calibrator for surface temperature sensors 19 4 3...
Page 3: ...alibration 52 8 4 Adjustment 52 9 Decommissioning and disposal 53 10 Technical data 54 10 1 Characteristics TP37 TP3M 54 10 2 Heating up and cooling times 56 10 2 1 10 2 1 TP 37 200 E TP 37 165 E TP 3...
Page 4: ...urrent This sign indicates dangers which could arise from handling of electric current WARNING CAUTION Risk of injury This sign indicates dangers that cause personal injuries that can lead to health d...
Page 5: ...rial and labora tory tasks Thus for example thermometers temperature switches thermostats resistance thermom eters and thermo elements can be directly connected and checked Versions The TP37 TP3M is a...
Page 6: ...e packaging Save the packaging for returning the instrument safely to the manufacturer for recal ibration or repair Scope of delivery and accessories Scope of delivery Accessories optional TP37 TP3M a...
Page 7: ...C or below 10 C Allow the calibrator to cool before you remove the test specimen clean the tank change the adapter sleeve or the calibration insert or switch off the machine CAUTION Material damage T...
Page 8: ...id Qualified personnel The personnel who are charged for the installation operation and maintenance of the TP37 TP3M must hold a relevant qualification This can be based on training or relevant tuitio...
Page 9: ...the temperature range permissible for the test sample Ensure that the test sample is securely fixed in the calibrator Use only suitable adapter sleeves or calibration inserts When doing so also ensur...
Page 10: ...CS 25 C 270 C 280 C Water Only use distilled water otherwise excessive limescale and soiling will build up in the cal ibrator tank Silicone oil Use only the silicone oil recommended here Always read...
Page 11: ...of the opening of the metal block The rear part of the housing holds a heat insulated calibration block with heating or cooling elements and an integrated sensor for the reference temperature In the...
Page 12: ...alibrator 4 3 Preparing of the calibrator They give the test specimen a secure fit and ensure optimum heat transfer Once all the preparations have been carried out the calibrator can be switched on 4...
Page 13: ...g tasks defined in the factory in which the basic settings of the calibrator are stored If desired customer specific test tasks can also be pre set These protected test tasks can be neither deleted no...
Page 14: ...t conditions p 55 4 1 Operating conditions Select a safe installation site for commissioning the machine Installation site and operating position Only suitable for indoor use do not use outdoors Opera...
Page 15: ...ne only with the approved supply voltage 10 1 Ensure that the mains voltage is the same as that specified on the type plate Please follow the local regulations of the energy supplier Connect the calib...
Page 16: ...E the tank must be emptied and cleaned to pre vent the adapter sleeve or the calibration insert from getting stuck Empty and clean the tank before you insert another adapter sleeve or calibration in s...
Page 17: ...of the test specimen The measurement element of the test specimen must be located in the ho mogeneous temperature zone of the adapter sleeve Please also follow the Details of the DKD technical committ...
Page 18: ...pot must be smaller than the inner diameter and must not touch the wall of the infrared insert Inserting The infrared insert is inserted into the metal block with the aid of the sleeve exchange tool R...
Page 19: ...the surface insert from getting stuck in the metal block IMPORTANT NOTICE The calibration of surface temperature sensors is very difficult and not uncontroversial The temperature sensor which are plac...
Page 20: ...valve The transport cover is equipped with a safety valve which is activated once the pressure reaches 1 5 bar This can result in hot steam being released Always unscrew the transport cover before pu...
Page 21: ...ation liquids supply varying calibration results due to their specific character istics Adjustment to the respective calibration liquid has to be carried out by the manufac turer In order to achieve t...
Page 22: ...calibration liquid causes contamination and can damage the calibra tor Ensure that the maximum fill level is not exceeded during operation The fill level in the tank or tub insert rises as a result o...
Page 23: ...using the sleeve exchange tool only for tub insert Place the magnetic stirrer in the tank tub insert Insert the sensor cage Insert the test specimens in the sensor cage This accounts for the volume of...
Page 24: ...or storage After transport storage or long periods of non use moisture can seep into the heating elements magnesium oxide For drying the calibrator must be slowly heated up During this process the ca...
Page 25: ...et damaged Switch off the calibrator only when the safe temperature range has been reached Press the key until the main window is displayed Press the key to switch off the calibrator The calibrator re...
Page 26: ...e window of the parameter is opened or displayed The windows Calibrator Set Up and Select measurement report are opened with the icons and The window Select Test Task is opened from the parameter fiel...
Page 27: ...st tasks and create or configure your own test tasks Pg 35 Switching off By using the icon you can switch the calibrator off 4 4 Switching on cool down and switching off Display range The reference te...
Page 28: ...From the windows Select Function 5 4 1 and Select DUT 5 5 1 k you can switch to the expert mode for administering and configuring Follow the instructions in the corresponding sections Changes to func...
Page 29: ...tion list displays the elements available in the window This can be available test tasks recorded measurement logs saved test specimens or functions of the cali brator The desired element is selected...
Page 30: ...s generated for the selection list and the relevant window is displayed Delete The selected entry in the selection list is deleted Search The selection list is searched for an entry for example Pg 35...
Page 31: ...e desired function by tapping on in the selection list The information on the function is immediately displayed in the information box From the toolbar you can accept the selected function or switch t...
Page 32: ...the parameter field of the desired parame ter The parameter s window is opened You can con figure the parameter there Name You can change the name of the function here After tapping the virtual keybo...
Page 33: ...Here you can select and manage existing test specimens You can create new test speci mens or tailor unprotected test specimens to match your requirements IMPORTANT When changing test specimens please...
Page 34: ...dow Configure DUT is opened Details pertaining to the window can be found in the following section 5 5 3 Configure DUT From the Manage DUT window you can use the icon to go to the window Configure DUT...
Page 35: ...ap on the icon to search for a test task A virtual keyboard with an input line is displayed Input the desired search term and confirm your input The result of the search is shown in the selection list...
Page 36: ...g mode you can set the parameters of one or more test point s IMPORTANT Dynamic designation and depiction of the parameter fields Depending on the selection of the Behaviour at test end Pg 37 individu...
Page 37: ...rm the inputs The new values are adopted and you will be returned to the previous window 5 6 3 2 Control off Step operating With these operating modes you can set the parameters of several test points...
Page 38: ...ield by tapping if the test points are to be approached in suc cession from the first to the last back to the first test point Middle parameter field The parameter field displays the current Behaviour...
Page 39: ...e information box in the window Select the desired function by tapping on in the selection list Confirm the selection by using the icon The new function is adopted and you will be re turned to the pre...
Page 40: ...name is adopted and you will be returned to the previous window Test value acquisition Information on the selected type of test value acquisi tion is displayed in the information box Select the desire...
Page 41: ...rator is dis played These data are the calibrator type the production date the version of the software the serial number the op erating hours total since the last calibration and the cali bration date...
Page 42: ...dress and subnet mask are requested from the network The two pa rameter fields are disabled In addition for Manual Input the IP address from the numeric keypad of the window and confirm the input with...
Page 43: ...ised Now tap on the parameter field Software update Follow the instructions on the screen Decimal places Here you can define the format of the temperature values in the windows Select the desired form...
Page 44: ...is recog nised Now tap the parameter field Import user files Follow the instructions on the screen Export user files You can use this parameter field to save all the user settings of test tasks test s...
Page 45: ...e desired measurement log by tapping on in the selection list The information on the measurement log is immediately displayed in the information box Delete measurement report On tapping the icon the s...
Page 46: ...r the calibrator has sufficient structural stability Starting the testing process IMPORTANT Parameter fields disabled During the testing process all the parameter fields with the exception of the Star...
Page 47: ...test point Probable remaining test duration for the current test point Time and date Reference used Current stirring speed Cycle counter in case of more than one pass Step counter for stepped operati...
Page 48: ...return to SIKA Costs incurred due to inadequate cleaning of the device and possible costs for disposal and or personal injuries will be billed to the operating company WARNING Risk of injury due to in...
Page 49: ...wnload www sika net images RMA Formular_Warenruecksendung pdf 8 Maintenance and cleaning Before maintenance and cleaning check whether the calibrator has cooled sufficiently 4 4 Cool down the calibrat...
Page 50: ...t the screen is dark and the fan is not running you should check the fuses and replace them if required Pull the mains connection cable from the calibrator Prise open the fuse compartment from the bot...
Page 51: ...ull the measuring insert out of the calibration block with the help of the sleeve ex change tool Clean the measuring insert and the calibration block at regular intervals Before a prolonged shutdown o...
Page 52: ...can vary from the measurement conditions prevailing at the time of calibration of the calibrator 11 For this case the TP37 TP3M offers the facility to store your own adjustment values This is possible...
Page 53: ...hing on cool down and Decommissioning Remove all connected sensors and devices Switch off the calibrator and disconnect the mains plug Empty the calibrator tank in case there is residual calibration l...
Page 54: ...0 5 C 1 C 0 4 C 0 3 C 0 5 C 1 C 0 1 C 0 3 C 0 5 C 1 C 0 1 C Emission degree Infrared 0 9994 0 9994 0 9994 Stability of the control Dry block Infrared Surface Micro bath 0 05 C 0 05 C 0 05 C 0 05 C 0 2...
Page 55: ...rotection EN 60529 IP 20 Connecting cable H05VV F 3 G 0 75 mm2 with angled protective contact plug and cold equipment plug Length 2 m Process variables Metal block Tank opening Borehole Depth 28 mm 15...
Page 56: ...and cooling times are dependent on the parameters of the test task used and the ambient conditions The following times are guide values for a room temperature of 23 C without settling processes 10 2...
Page 57: ...TP37 TP3M Technical data Technical changes reserved 57 10 2 3 TP 3M 165 E Dry block infrared and surface Micro bath Water and silicone oil...
Page 58: ...Technical data TP37 TP3M 58 SIKA Ba_TP37 TP3M_en 07 2015 10 2 4 TP 3M 255 E Dry block infrared and surface Micro bath Water and silicone oil...
Page 59: ...ra ture block calibrator If this is the case the calibration is only effective if the calibrator was used with a corresponding heat transfer medium With the calibration of thermometers with an outer d...
Page 60: ...07 2015 Sensors and Measuring Instruments Flow Measuring Instruments Test and Calibration Instruments SIKA Dr Siebert K hn GmbH Co KG Struthweg 7 9 D 34260 Kaufungen Germany 49 0 5605 803 0 49 0 5605...