MOUNTING INSTRUCTIONS:
1. Attach the cast junction box to surface with screws (hardware by
others)
2. Run conduit to junction box if application calls for it and pull
supply leads into junction box with at least 6” lead showing.
Location Environments
.
3. Place gasket (from polybag) and make wiring connections from
driver in Heatsink to supply leads (See wiring diagram)
4. Remove Globe, with the gasket in place, attach Heatsink to
junction box by using the two (2) screws provided in polybag.
Insert the screws through the holes on the inside of Heatsink. Next
align the screws with the holes on the “Adaptor Plate” mounted
on the “Junction Box” and tighten. Do not touch LED and do not
damage or soil the reflector during installation.
(Care must be given to not cross thread)
6. Replace Guard onto Globe. (Care must be given not to cross
thread. Do not over tighten set screw when securing guard)
VAPOR PROOF LIGHT
SUITABLE FOR WATTAGES:
14W
4.52’’ x 4.52’’ x 11.04’’
MOUNTING INSTRUCTIONS
FIXTURE IS SUITABLE FOR WET LOCATION
DO NOT INSTALL CELINING MOUNT VERSION OF THIS FIXTURE ON WALL
INSTALL W/ GLOBE FACING DOWN ONLY
NOT FOR WASH DOWN APPLICATION NOT FOR USE IN RANGE HOODS
CAUTION:
weatherproof silicone sealant (not included) around the edge of the Wall Box and/or Junction Box. This is especially important with an uneven
wall surface. Silicone all plugs and unused conduit entries.
IMPORTANT:
READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE.
ordinances. These codes and ordinances supersede any and all instruction contained herein. Installation should be performed only by a
licensed and bonded electrician and a person familiar with the construction and operation of the product and the hazards involved in the
installation and operation of this product. Proper grounding is required for safety.
Make certain power is OFF before installing or maintaining
for the the product not installed under those guidelines and those contained in this document. See wiring diagram on back.
109.8mm
[4.32"]
Gasket EVA
Junction Box
Gasket
Gasket
Phillips pan head Brass screws
#10 - 24 UNC x 0.75”
2pcs
Heatsink
Globe Gasket
Phillips flat head screws
#10 - 24 UNC x 1.875”
2pcs
Globe
Guard
109.0mm[4.29"]
114.8mm[4.52"]
141.2mm
[5.56"]
280.5mm[11.04"]
243.0mm[9.57"]
This fixture must be wired and installed in accordance with the National Electrial Code and all state and applicable local codes and
fixture.
Failure to do so may increase the risk of personal injury, property damage, fire, and death. The manufacturer takes no responsibility
For proper weatherproof function,gaskets must be seated properly and all screws inserted and tightened firmly. Apply
Note: Be sure to use Teflon tape to seal 1/2” NPT threads for Wet
5. Replace Globe onto fixture by threading until tight