background image

Model: 065-7932

16-Port Gigabit Web Smart Switch 
with 4 Mini-GBIC (SFP) slots

USER´S  MANUAL

Summary of Contents for 065-7932

Page 1: ...Model 065 7932 16 Port Gigabit Web Smart Switch with 4 Mini GBIC SFP slots USER S MANUAL...

Page 2: ...llation 7 Installing Network Cables 8 Description of Switch Functions 9 Jumbo Frame 9 Flow Control and Backpressure 9 Mirror 9 VLAN 9 Trunk Aggregation 9 Quality of Service QoS 9 SNMP 9 Management gui...

Page 3: ...ace 25 Start up and Terminal configuration 25 Login Logout Procedures 25 Command Hierarchy 25 Entering Commands 26 Command Description 26 System Commands 26 Console Commands 27 Port Commands 27 VLAN C...

Page 4: ...protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the nstructi...

Page 5: ...ort automatically disables its corresponding copper port The management functions enable efficient network usage VLAN reduces the collisions caused by broadcasting Port Aggregation enlarges the bandwi...

Page 6: ...their interchangeable Gigabit RJ 45 copper combo ports the last 4 copper ports Use of a mini GBIC slot automatically disables its corresponding copper port Port Operation The auto negotiation feature...

Page 7: ...a minimum space around the unit of 25mm is recommended 2 the Switch and relevant components are far from sources of electrical noise such as radios transmitters and broadband amplifiers 3 the Switch s...

Page 8: ...o make a valid connection and obtain optimal performance it is vital to use the appropriate cables that correspond to the different transmitting receiving speeds 3 To choose a suitable cable please re...

Page 9: ...able to monitor the traffic through the specified port VLAN This Switch supports Virtual LAN which means the network can be segmented into groups to reduce collisions caused by wide broadcasting The...

Page 10: ...in the following configuration 1 Data rate 115200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings make sure that The Function arr...

Page 11: ...factory default value of User Name and Password is admin Homepage After successful log in the SYSTEM Configuration page appears this is also the Homepage You can click on the hyperlinks on the left si...

Page 12: ...ormation and allows users to configure most of these properties see table under screenshot for details To save the configuration of the system click Apply Note After applying a new IP address a new lo...

Page 13: ...shows the link status of each port and allows users to configure speed flow control and maximum frame size for each port To save the configuration of the system click Apply You can also click the Refr...

Page 14: ...s to configure To add new VLAN groups 1 Fill in a VLAN ID from 2 to 4094 in the VLAN Port column 2 Select the ports for each VLAN group 3 Click the Apply button to execute To delete a VLAN group 1 Rem...

Page 15: ...www signamax eu 15 PVID When the VLAN enabled Switch receives a tagged packet the packet will be sent to the port s default VLAN according to the PVID port VLAN ID of the receiving port...

Page 16: ...ve the settings There are three aggregation modes for you to set up SMAC DMAC and XOR SMAC mode selects the path of packets according to Source MAC while DMAC mode selects path according to Destinatio...

Page 17: ...e QoS Port based QoS allows users to configure each port as having a high or low priority To assign a priority level to each port 1 Select Port in the Mode column for those ports that are going to fun...

Page 18: ...ck the Tag priority button The Tag Priority Setting page shows up 3 Select the port that you are going to configure from the drop menu 4 Set the priorities as high or low for each Priority Tag type 5...

Page 19: ...riority Setting page shows up 3 Set the priorities as high or low for each precedence type 4 Click the Apply button again to execute your configuration Mirror The Mirror function copies all the packet...

Page 20: ...ice supports SNMP management which allows network administrators to monitor and configure this device with SNMP software To allow this device to be managed via SNMP 1 Select enable in the drop menu 2...

Page 21: ...aximum of 16 devices respectively for auto and manual modes Auto Search 1 Click the Apply button to start 2 The devices being found are listed below 3 Click the IP address hyperlink to get access to t...

Page 22: ...ics Detailed Statistics The Detailed Statistics is provided for users to see the detailed transmitting and receiving status of each port Please click the hyperlinks above to select a port You may also...

Page 23: ...ick on the appropriate flash in the Boot image number column and click the Apply button to execute Software Upload This Software Upload page allows users to upgrade firmware for this Switch To perform...

Page 24: ...USER S MANUAL 24 www signamax eu Product Specifications s...

Page 25: ...o get the username and password for login The default username and password are admin and admin Note We recommend that you configure a new username and password to prevent unauthorized users from acce...

Page 26: ...on commands QoS QoS commands Mirror Mirror commands IP IP commands SNMP SNMP commands Ratelimit Rate setup commands Exit Logout commands System Commands Commands at System level System Configuration a...

Page 27: ...timeout Console Prompt prompt string Console Configuration Description Show configured console prompt and timeout Console Timeout timeout Description Set or show the console inactivity timeout in seco...

Page 28: ...Enable disable flow control default Show flow control mode Port Admin portlist enable disable Description Set or show the admin state for the port portlist Port list default All ports enable disable...

Page 29: ...ID list VLAN Egress portlist untagged tagged Description Set or show the VLAN egress mode setting for the port Egress untagged ports will strip the VLAN tag from received frames Egress tagged ports wi...

Page 30: ...gr Mode smac dmac xor Description Set or show link aggregation traffic distribution mode smac dmac xor Aggregation mode SMAC DMAC or XOR default Show mode QoS Commands Commands at QoS level QoS Config...

Page 31: ...Internal class of service default Show class QoS DiffServ dscpno class Description Set or show the IP Differentiated Services mapping dscpno IP DSCP number 0 7 class range low normal medium high Mirr...

Page 32: ...vate or deactivate the Web management enable disable Enable disable Web management default Show Web management SNMP Commands Commands at SNMP level SNMP Configuration SNMP Community get set community...

Page 33: ...2 1024 2048 3072K default Show rate Ratelimit Configuration Description Show the Ratelimit setting Ratelimit Setup traffic type option Description Set or show the ratelimit configuration The allowed f...

Page 34: ...www signamax eu K E E P I N G Y O U R W O R L D C O N N E C T E D...