SIGMATEK STO 081 Operating Manual Download Page 1

 

 

  
 
 
 

STO 081 

 

S-DIAS Safety 

Digital Output Module 

 
 
 
 
 
 
 
 

Operating Manual 

 

 Date of creation: 18.12.2013 

 Version date: 04.11.2020 

 Article number: 20-892-081-E 

Summary of Contents for STO 081

Page 1: ...STO 081 S DIAS Safety Digital Output Module Operating Manual Date of creation 18 12 2013 Version date 04 11 2020 Article number 20 892 081 E...

Page 2: ...rt of this work may be reproduced edited using an electronic system duplicated or distributed in any form print photocopy microfilm or in any other process without the express permission We reserve th...

Page 3: ...of eight actuator signals to for example control relays valves etc The safety related STO 081 is ideal for use in systems with optional modules and interface variables according to Safety System Handb...

Page 4: ...Conformity Declaration 10 3 3 Safety Relevant Parameters 11 3 3 1 Mounting Position Horizontal 0 55 C Ambient Temperature 11 3 3 2 Mounting Position Horizontal 55 60 C Ambient Temperature 11 3 4 Compa...

Page 5: ...t 19 6 1 Status LEDs 20 6 2 Applicable Connectors 20 6 3 Label Field 21 7 Wiring 22 7 1 Wiring Example 22 7 2 Note 23 8 Mounting 24 9 Disposal 26 10 Hardware Class STO081 27 10 1 Interfaces 28 10 1 1...

Page 6: ...ANGER DANGER Identifies an immediate danger with high risk which can lead to immediate death or serious injury if not avoided Indique un danger direct haut risque d un d c s imm diat ou des blessures...

Page 7: ...ning Avertissement d une surface chaude Danger for ESD sensitive components Les signes de danger pour les composants sensibles aux d charges lectrostatiques This symbol identifies important or additio...

Page 8: ...nformations importantes Distribuez la documentation technique aux secteurs de la vente et ou de la location du produit Acceptance of the Safety Guidelines Before handling the product belonging to this...

Page 9: ...tenance and decommissioning of control and automation technology products in general as well as safety related products especially can only be performed by qualified personnel Qualified personnel in t...

Page 10: ...module outside of the technical data described in this handbook Utilisation pr vue Les modules de s curit sont con us pour une utilisation dans les applications sollicitant un niveau de s curit et r p...

Page 11: ...Safety modules the documentation is complete and in readable condition and available at the site of operation Obligation de diligence L utilisateur doit s assurer que les modules de s curit ne sont ut...

Page 12: ...g European directives 2006 42 EG Directive of the European Parliament and of the Council of 17 May 2006 on Machinery and Change to the Directive 95 16 EC machine guideline 2014 30 EU Electromagnetic C...

Page 13: ...according to EN ISO 13849 1 2 Structure Two channel redundant diverse 3 3 2 Mounting Position Horizontal 55 60 C Ambient Temperature Output Module Safety Parameters Safety Levels STO 081 including CPU...

Page 14: ...max of 45 C ambient temperature 8 A up to a max of 55 C ambient temperature 6 A up to a max of 60 C ambient temperature Brake voltage with switching off inductive loads typically 0 85 V Maximum switc...

Page 15: ...e Timing A fuse for the supply voltage must be installed which can sufficiently limit voltage and current Un fusible conforme aux limites de la tension et du courant d alimentation doit tre pr sent en...

Page 16: ...STO 081 S DIAS SAFETY DIGITAL OUTPUT MODULE Page 14 04 11 2020 4 1 2 Maximum Capacitive Load C F at Load Current I A I A L mH C F 0 6400 1 25 0 5 1600 3 13 1 400 5 2 100 8 75...

Page 17: ...e internal output circuit of the STO 081 4 3 Electrical Requirements Voltage supply from Safety bus 12 V Current consumption on the Safety bus 12 V supply typically 42 mA maximum 50 mA Voltage supply...

Page 18: ...STO 081 S DIAS SAFETY DIGITAL OUTPUT MODULE Page 16 04 11 2020...

Page 19: ...e maximum environmental temperature by 0 5 C per 100 m Operating conditions Pollution degree 2 EMC resistance in accordance with 61000 6 7 2015 Generic standards Immunity requirements for equipment in...

Page 20: ...STO 081 S DIAS SAFETY DIGITAL OUTPUT MODULE Page 18 04 11 2020 5 Mechanical Dimensions...

Page 21: ...d Pin 4 is internally bridged Only one GND pin pin 3 or pin 4 is required to power the module The bridged connections may be used for further looping of the 24 V supply and the GND supply However it m...

Page 22: ...ith spring terminals included in delivery The spring terminals are suitable connecting ultrasonically compacted ultrasonically welded strands Connections Stripping length Sleeve length 10 mm Plug in d...

Page 23: ...DULE STO 081 04 11 2020 Page 21 6 3 Label Field Manufacturer Weidm ller Type MF 10 5 CABUR MC NE WS Weidm ller article number 1854510000 Compatible printer Weidm ller Type Printjet Advanced 230V Weidm...

Page 24: ...STO 081 S DIAS SAFETY DIGITAL OUTPUT MODULE Page 22 04 11 2020 7 Wiring 7 1 Wiring Example...

Page 25: ...ring circuits Protective circuits for all relays RC networks or free wheeling diodes Correct wiring to ground The ground bus should be connected to the control cabinet when possible Si possible la ter...

Page 26: ...are mounted on the DIN rail as a block and secured with latches The functional ground connection from the module to the DIN rail is made via the grounding clamp on the back of the S DIAS modules The...

Page 27: ...S DIAS SAFETY DIGITAL OUTPUT MODULE STO 081 04 11 2020 Page 25 Recommended minimum distances of the S DIAS modules to the surrounding components or control cabinet wall a b c distances in mm inches...

Page 28: ...STO 081 S DIAS SAFETY DIGITAL OUTPUT MODULE Page 26 04 11 2020 9 Disposal For the disposal of the product the respective guidelines possibly country specific must be observed and followed...

Page 29: ...10 Hardware Class STO081 Hardware Class STO081 for the S DIAS STO 081 digital output module This hardware class is used to control the STO 081 hardware module with 8 Safe digital outputs More informa...

Page 30: ...lt which means that the S DIAS hardware module at this position is mandatory for the system and can under no circumstances be disconnected or return an error Otherwise the entire hardware deactivated...

Page 31: ...cel other errors starting with version 6 The canceling of errors is forwarded to the Safety CPU and canceled with all other errors in the Safety CPU Caution Canceling can activate safety outputs and t...

Page 32: ...81 S DIAS SAFETY DIGITAL OUTPUT MODULE Page 30 04 11 2020 10 1 3 Communication Interfaces ALARM Downlink With this downlink the corresponding alarm class can be placed via the hardware editor 10 2 Exa...

Page 33: ...dule while voltage is applied 23 03 2015 15 5 Connector Layout Changed mnemotechnic verse 26 03 2015 16 5 2 Applicable Connectors Added connections 07 05 2015 New writing EN ISO 13849 1 2 18 05 2015 1...

Page 34: ...ion of the safety relevant parameters Corrections environmental conditions Corrections due to CE 14 11 2019 9 Supported Cycle Times Chapter added 02 12 2019 2 3 Safety Relevant Parameters Values updat...

Reviews: