5 Interfaces
5.1 Mains input (X2)
The mains input is prepared for direct mains 115 VAC or 115 VAC to 230 VAC input volt-
age, depending on the selected power supply module. If the neutral point of the connected
mains is not grounded, an over voltage protection unit has to be installed in the input of the
switchgear cabinet (
page 36).
Note: If the DC-link of two or more MDD 100 systems are linked with the
same supply voltage, the mains inputs must also be linked.
1-phase connection of the MDP 102-1 power supply module:
5
5
6
6
7
7
4
4
X2
L1
L2
L3
PE
PE
L1
N
Mains contactor
3 ~
=
V
V
V
V
V
V
V
V
Power supply Module
Di
re
c
t
m
a
in
s
1
x
1
1
5
V
-10%
..
2
3
0
V
+10
%