3.5 Safety-Relevant Parameters
Input Module
Safety Parameters
1)
HGW 1033-3
PFH
D
= 2.7E-09 (1/h)
MTTF
D
= 766 years
DC = 99 %
SFF = 99.81
Confirmation switch
B
10D
= 100,000
Emergency stop switch
B
10D
= 250,000
Key switch
B
10D
= 10,000
Transmission route (WLAN)
between the HGW 1033-3 and
Safe CPU. Worst-Case
Calculation.
PFH
D
= 1.71E-10
3.6 Wireless System Operation
INFORMATION
Technical changes to the device (such as different antennae), as well
as improper use can lead to the loss of the FCC license and generate
interference, which can affect the function of nearby devices.
Les changements techniques apportés à l'appareil (comme les
différentes antennes), ainsi qu'une utilisation incorrecte peuvent
entraîner la perte de la licence FCC et générer des interférences, ce qui
peut affecter le fonctionnement des appareils voisins.
Please note the national regulations and standards when operating the
wireless device!
Veuillez respecter les prescriptions et normes nationales lors de
l'utilisation de l'appareil radio !
1)
Depending on the application, the probability of failure must be determined for the included electromechanical
components based on the B
10D
values listed here and included in the calculation for the entire system. The Safe CPU
SCP 111 must also be calculated in.