10.4“ HANDHELD CONTROL PANEL
HBG 1011
16.08.2018
Page 17
3.6
Miscellaneous
Article number
12-245-1011
Hardware version
1.x
Software version
1.x
Connector cable
optionally available (see documentation for connection cables for operating
devices)
Standard
UL 508 (E247993)
Approvals
CE, TÜV EC type tested,
c
UL
US
On HMI-Link extenders with SW version 1.x, HMI-Link display units/control panels
with SW version 1.x must be used.
Sur HMI-Link avec des extenseur versions SW 1.x, HMI-Link unités d'affi-
chage/panneaux de commande avec la version SW 1.x doivent être utilisées.
3.7
Environmental Conditions
Storage temperature
-
10 … +60 °C
Operating temperature
0
… +45 °C
Humidity
10-90 %, non-condensing
Operating conditions
pollution degree 2
altitude up to 2000 m
EMC stability
EN 61000-6-2 (industrial area)
(increased requirements according to IEC/EN 62061)
Shock resistance
EN 60068-2-27
150 m/s²
Vibration tolerance
10 m/s²
Protection type
EN 60529
IP54
(with USB cover only)
Free fall
(without packaging)
DIN EN 60068-2-31
500 mm