ETV 1591-H
CONTROL PANEL
Page 28
24.03.2015
ESetCableType
Description
Request-ID
Instruction Sequence
Sets the battery extension cable
type used.
0x83
Open connection
Send 4-byte Request-ID (0x04) to Pipe
Send 1-byte cable type to Pipe
0x00 = Type0 = battery connected directly
0x01 = Type1 = not used
0x02 = Type2 = battery extension cable (1 meter)
0x03 = Type3 = not used
0x04 = Type4 = not used
Read 1-byte (boolean) answer
Close connection
Answer
ByteNo.
Data
type
Info
1
BOOL
FALSE = Error
TRUE = The cable type was enabled/disabled in the configuration
EResetBatteryExchangeNeeded
Description
Request-ID
Instruction Sequence
Resets the "Battery exchange
needed" warning from the EGet-
BatteryExchangeNeeded Pipe
function.
0xC0
Open connection
Send 4-byte Request-ID (0x04) to Pipe
Read 1-byte (boolean) answer
Close connection
Answer
ByteNo.
Data
type
Info
1
BOOL
FALSE = Error
TRUE = The Battery exchange needed" status was reset