Relay specifications
Number of relays
1 x Relay output (contacts S3, S4)
Relay types
1 x normally open
Power supply
+24 V DC
Switching time
<10 ms
Switching range
Max. 30 V DC/ min. 100 µA, max. 0.5 A
Switching power
Max. 42 V AC / min. 100 µA, max. 0.5 A
Intended only for connection to an isolated secondary power supply rated 24 VDC. Fuse in
accordance with UL246 rated max. 4A must be connected between the power supply and
device terminal.
Safety conformity
Safety Integrity Level according
to IEC EN 62061
SIL 3
Performance Level according to
EN ISO 13849-1
PLe
Probability of failure per hour
PFH
D
[10
-9
]
0,3
Mean time to dangerous failure
MTTF
D
symmetrized [Years]
High
Proof Test Interval [Years]
20
Miscellaneous
Article number
16-059-013
Hardware version
2.x
Standardization
UL (E336350)