DIAS-DRIVE 210-23
Page 56
30.03.2021
27
Motor
parameter
error
─ For motors with EnDAT
®
or
HIPERFACE
®
encoders,
no M - parameters were
found in the encoder.
─ Encoder was not loaded with M
- parameters.
─ Encoder defective.
─ Signal lines or connector defec-
tive, incorrectly wired or there
are breaks in the cables.
28
Multiturn error
─ For EnDAT
®
or
HIPERFACE
®
Multiturn
encoders, an error has
occurred during the exten-
sion to >4096 turns.
─ Motor with a multiturn encoder
was exchanged
─ Encoder defective.
29
Total power limit
reached
─ The power of all axes has
exceeded the maximum
load.
Reduce load
─ Drive power too low
30
Reserved
31
Reserved