3.3 DC-link (X1B)
To bridge the intermediate circuit voltage with other servo amplifiers, the X1B/2 (+DV) and 3
(-DC) connectors can be used.
The power from the intermediate circuit of different servo amplifiers can be distributed using
the method.
Note:
If the intermediate circuit is bridged within a group of amplifiers, the
main power supply in this group must also be bridged.