S-DIAS AXIS MODULE
DC 061-1
23.08.2019
Page 11
2.6
Electrical Requirements
Power 24 V (X4)
+18-30 V, Class 2
(1)
Current consumption of the
+24 V supply
load-dependent (holding brake)
Supply voltage motor (X2)
+18-55 V
(2)
Switching threshold for motor
voltage monitor
minimum 18 V
maximum 65 V
Current consumption of motor
supply
load-dependent (motor)
Voltage supply from S-DIAS bus
+24 V
Current consumption on the
S-DIAS bus (+24 V supply)
typically 70 mA
maximum 80 mA
(1)
For USA and Canada:
The supply (X4) must be limited to:
a) max. 5 A at voltages from 0-20 V DC, or
b) 100 W at voltages from 20-60 V DC
The limiting component (e.g. transformer, power supply or fuse) must be certified by
an NRTL (Nationally Recognized Testing Laboratory).
(2)
Pour les États-Unis et le Canada:
L’alimentation (X4) doit être limitée à:
a) max. 5 A pour des tensions de 0-20 V DC, ou
b) 100 W pour des tensions de 20-60 V DC
Le composant imposant la limite (par exemple, transformateur, alimentation élec-
trique ou fusible) doit être certifié par un NRTL (National Recognized Testing Labora-
tory, par exemple, UL).
(2)
The motor supply (X2) must be connected with an intermediate circuit capacitance
appropriate for the application (at least 2000 µF/100 V).
Summary of Contents for DC 061-1
Page 15: ...S DIAS AXIS MODULE DC 061 1 23 08 2019 Page 13...
Page 17: ...S DIAS AXIS MODULE DC 061 1 23 08 2019 Page 15 3 Mechanical Dimensions...
Page 24: ...DC 061 1 S DIAS AXIS MODULE Page 22 23 08 2019 5 Wiring 5 1 Wiring Example...
Page 36: ...DC 061 1 S DIAS AXIS MODULE Page 34 23 08 2019...
Page 38: ...DC 061 1 S DIAS AXIS MODULE Page 36 23 08 2019...
Page 40: ...DC 061 1 S DIAS AXIS MODULE Page 38 23 08 2019...
Page 42: ...DC 061 1 S DIAS AXIS MODULE Page 40 23 08 2019...