DC 061-1
S-DIAS AXIS MODULE
Page 10
23.08.2019
2.4
Holding Brake Specifications
Output voltage
24 V
Maximum continuous current
500 mA
Short-circuit protection
yes
Maximum switch-off energy
(inductive load)
50 mJ
2.5
Regen Brake Specifications
Type
external power resistor
Output
GND switching
Maximum current
10 A
(1)
Lowest possible resistance
6 Ω
(2)
Short-circuit protection
yes
Threshold regen braking on/off
60 V/55 V
(1)
Regen braking must be dimensioned according to the application. For most applications, a 10 Ω/50 W resistor is
sufficient. If multiple DC 061-1s are driven with one intermediate circuit supply, it is possible to equip only one
module with regen braking. The recommended regen resistor is available at SIGMATEK under the article number
20-014-061-Z1.
(2)
The resistor must be dimensioned with regard to its maximum power dissipation in accordance with the braking
power occurring in the application. However, the permissible short-term power must be at least P=U
2
/R, i.e.
60
2
/R.
Hot surface warning!
Danger of burns if touched!
The surface of the braking resistor can become very hot during operation
and is still hot some time after operation.
Avoid touching the surface of the braking resistor even some time after
operation.
Summary of Contents for DC 061-1
Page 15: ...S DIAS AXIS MODULE DC 061 1 23 08 2019 Page 13...
Page 17: ...S DIAS AXIS MODULE DC 061 1 23 08 2019 Page 15 3 Mechanical Dimensions...
Page 24: ...DC 061 1 S DIAS AXIS MODULE Page 22 23 08 2019 5 Wiring 5 1 Wiring Example...
Page 36: ...DC 061 1 S DIAS AXIS MODULE Page 34 23 08 2019...
Page 38: ...DC 061 1 S DIAS AXIS MODULE Page 36 23 08 2019...
Page 40: ...DC 061 1 S DIAS AXIS MODULE Page 38 23 08 2019...
Page 42: ...DC 061 1 S DIAS AXIS MODULE Page 40 23 08 2019...