WLAN HGW BASE STATION
BWH 001
02.10.2018
Page 35
8.2.5
Placing the Installation Number
Place a unique, 2-digit number on the installation over which the handheld operating panel
should be coupled with the machine.
This number can only occur once in the machine park. Otherwise, the operating panel could
be unintentionally coupled with a non-participating machine and lead to confusion.
Ensure the number is placed visibly.
Note the unique number assignment in the system plan.
8.3
Mounting Help
For mounting, a drill template is available for download. In addition to the boreholes, it also
contains the necessary space for the mounted HGW around the base station.
8.4
Wiring
The base station BWH 001 is connected via the M12 connector.
The connector socket is documented in chapter 6.1.1.
1) Turn off the current supply.
2) Install the wiring. Ensure the strands are equipped with ferrules and the shielding is
connected (see 8.4.1).
3) Turn the supply on again.
For the dimensions of the wiring, the power loss / voltage drop in the supply
lines must be taken into consideration. The voltage to the base station must
be within the specified limits.