Sigma-tech
Reguleated DC Power Supply Unit
Model : SMP-40300P
Serial No : JU14-1 4 6 2
User Manual
Sigma-Tech
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
Page 1: ...Sigma tech Reguleated DC Power Supply Unit Model SMP 40300P Serial No JU14 1 4 6 2 User Manual Sigma Tech 243 2 Tel 032 675 3903 Fax 032 675 3905 http www tech sigma com...
Page 2: ...Overview 2 Important Instructions Sigma tech 6 1 Terminal Block Diagram 6 2 Input or Output Terminal Block 4 4 Name and functions of each part 4 3 Name and functions of each part 5 How to use 7 Instu...
Page 3: ...e DC power for both constant voltage and constant current It is also protected against any access Please check the standard before applying the input D It displays the access of Juper Code The output...
Page 4: ...n excess current it is controlled as a constant curent at the maximum current to decrease output voltage proportional to the impedence in the load It ends up preventing the overcurrent The voltage bec...
Page 5: ...rrent fully counterclockwise 3 Make sure you connect the load with the output terminal Please connect one end of ordinary outut terminal and to Frame Ground and earth on it 4 Set the current you need...
Page 6: ...ould be on to activate DC output Remote function is optional 2 Local function 2 A Lamp Blue will be turn off if remote s w is at local 2 B Facial voltage volume control the voltage 3 Protection functi...
Page 7: ...nd cotton flannel B The Internal Remove the dust with vacuum cleaner after the power code is plugged out C Please check the insulation resistance frequently D No strange sound is accepted the life of...
Page 8: ...mp 14 Output On Off S W 15 Output Test Point 13 Fan Motor S W 1 Power S W 2 Current Viktage Display 243 2 Tel 032 675 3903 Fax 032 675 3905 http www tech sigma com 12 Output Current VR Output current...
Page 9: ...side turn OCP ADJ until the value is over predefined power value Sigma tech 243 2 Tel 032 675 3903 Fax 032 675 3905 http www tech sigma com 1 Voltage and Current setting 3 Over Current Protect OCP set...
Page 10: ...ltage output of power is over the set value The current output of power is over the set value 243 2 Tel 032 675 3903 Fax 032 675 3905 http www tech sigma com B Err FND configuration Over Current Prote...
Page 11: ...D display the information of voltage current and etc B the kinds of error C Button function will stop Then turn off the power and turn on again OCP The output voltage is over OCP set value OCP set the...
Page 12: ...clockwise to set required current The current setting mode will be back after 10 seconds C OVP setting mode Push OVP button 1 time Then turn OVP ADJ VR clockwise to set required OVP value THE OVP mode...
Page 13: ...ere Pin No 2 Earth Pin No 1 R type Pin No 2 S type AC 220Volt 60Hz 3 Pin No 3 T type 4 Input Terminal Block 243 2 Tel 032 675 3903 Fax 032 675 3905 http www tech sigma com Pin No 1 S Sigma tech 6 Back...
Page 14: ...ectrical 14 50 80 250 allowable current A 8 30 60 200 In case of output wire see below Wire thickness mm 243 2 Tel 032 675 3903 Fax 032 675 3905 http www tech sigma com Sigma tech capacity If not it m...
Page 15: ...3 2 Tel 032 675 3903 Fax 032 675 3905 http www tech sigma com F S 2 5 level Weight about Size Maximum Case Size and weight may be different according to the specification Stability of CV less than 0 0...
Page 16: ...Sigma tech 243 2 Tel 032 675 3903 Fax 032 675 3905 http www tech sigma com 9 Outside view...
Page 17: ...0V Safety device 10 Over Voltage Protectot OVP Over Current Protectot OCP Cooling System Air cooled Voltage Indicator 16 Bit A D 40 00 Volt Current Indicator 16 Bit A D 300 0 mAmpere Line Regulation 1...
Page 18: ...ters including fire earthquake and thunder By wrong power setting By repair or remodeling of others excluding sigma tech and the purchasing site 1 Warranty period is 2 years The repair cost will be fr...