16
User Manual
Command Format
[:SENSe]:FREQuency:OFFSet
[:SENSe]:FREQuency:OFFSet?
Instruction
Sets the frequency offset of the spectrum analyzer.
Gets the frequency offset.
Parameter Type
Float, unit: Hz, kHz, MHz, GHz
Parameter Range
-
100 GHz ~ 100 GHz
Return
Float, unit: Hz
Example
:FREQuency:OFFSet 1 GHz
3.1.4
Freq Step
Setting the value of Freq Step will change the direction key step of center frequency, start
frequency, stop frequency and frequency offset.
⚫
At a fixed step change the value of the center frequency can reach the purpose of switching
measurement channels rapidly and continuously.
⚫
There are two kinds of frequency step modes
:
Auto
and
Manual
. In Auto mode, the Freq step
is 1/10 of the span in Non-zero span or equals the RBW while in Zero Span. In Manual mode,
you can set the step using the numeric keys.
Command Format
[:SENSe]:FREQuency:CENTer:STEP[:INCRement]
[:SENSe]:FREQuency:CENTer:STEP[:INCRement]?
Instruction
Specifies the center frequency step size.
Gets the center frequency step.
Parameter Type
Float, unit: Hz, kHz, MHz, GHz
Parameter Range
1 Hz ~ 28 GHz
Return
Float, unit: Hz
Example
:FREQuency:CENTer:STEP 2 MHz
Command Format
[:SENSe]:FREQuency:CENTer:STEP:AUTO OFF|ON|0|1
[:SENSe]:FREQuency:CENTer:STEP:AUTO?
Instruction
Specifies whether the step size is set automatically based on the span.
Gets center frequency step mode.
Parameter Type
Boolean
Parameter Range
OFF|ON|0|1
Return
0|1
Example
:FREQuency:CENTer:STEP:AUTO OFF
Summary of Contents for SSA5083A
Page 1: ...User Manual EN_01A SSA5085A SSA5083A Spectrum Analyzer...
Page 2: ......
Page 4: ......
Page 29: ...User Manual XXV 10 2 TROUBLESHOOTING 225...
Page 30: ......
Page 97: ...User Manual 67...
Page 259: ......