ICD-1500-Adapter-Boards
© SightLine Applications, Inc.
3
5
Serial Port and GPIO Maps
5.1
Serial Port
Table 1: 1500-OEM and Adapter Boards Serial Ports
Hardware
Reference
Serial 0
Serial 1
Serial 2
Notes
Linux
Reference
/dev/ttyO0
/dev/ttyO1
/dev/ttyO2
SOM Port
Number
A
C
B
The Torpedo SOM hardware uses a different
nomenclature in the documentation. The SOM
serial port (A, B, C) maps to the SLA serial port (0,
1, 2).
Used for:
Command and Control
and debug. Recommend
allowing access for
troubleshooting.
Command and Control
and general customer
use/passthrough.
Primarily camera control
passthrough, can be used
for general customer
use/passthrough or
command and control.
Serial Port
Access
Pinouts
Connector, Pin
Connector, Pin
Connector, Pin
1500-OEM
Rx
Tx
level
Rx
Tx
level
Rx
Tx
level
Voltage levels of serial 1 and 2 are set by VIOSEL
input J4,46.
J3,6
J3,5
3.3V
J4,15
J4,16
Note
J4,1
J4,2
Note
System Interface Boards
Notes
SLA-1500-AB
(Rev J)
J2,4
J7,2
J2,3
J7,3
RS232
J13,3
J13,2
RS232
J14,3
J14,2
RS232
SLA-1500-nAB
J2,4
J2,3
RS232
SLA-1500-mAB
J8,4
J8,3
RS232
J7,30
J7,29
3.3 V
Ser 2 (J7) is only 3.3V when connected to the FLIR
Tau camera.
Camera Interface Boards
Notes
SLA-1500-
Sony / Tamron
J6,3
J6,2
3.3V
J3,3
J1,19
J3,2
J1,18
3.3V
5V
J1 is KEL micro-coax to camera.
SLA-1500-CL
J2,19+
J2,6 -
J2,20+
J2,7 -
3.3V
Serial 2 is translated to LVDS serial for camera
comms via J2
SLA-1500-
HDMI
J1,3
J1,2
3.3V
SLA-1500-HIT
J3,3
J3,2
3.3V
J1,35
J1,36
3.3V
J1 is FFC ribbon to camera
SLA-1500-FPC
J2,3
J2,2
Note
J1,16
J1,17
Note
At ribbon cable connector J1.
Voltage levels are set on the camera side board
(see below)
If no camera-side adapter is connected to FPC
ribbon, neither serial port is available without
setting VIOSEL voltage level.
SLA-FPC -
Boson
Pin out at
camera side has
opposite pin-
out (pin 1 on
OEM to pin 39
at camera side)
1.8 V
Sets VIOSEL and serial port levels to 1.8V.
SLA-FPC-DRS
Tamarisk
1.8 V
Sets VIOSEL and serial port levels to 1.8V.
SLA-FPC -Tau
3.3 V
Sets VIOSEL and serial port levels to 3.3 V
SLA-FPC -
Airborne
2.8 V
Sets VIOSEL and serial port levels to 2.8 V
SLA-1500-FFC
to
SLA-FFC-TAU
J2,3
J2,2
3.3 V
J1,30
J1,29
3.3 V
J1 is FFC ribbon to Tau camera.
Voltage levels set by Tau camera so only 3.3 V
when camera is connected.
IMPORTANT
: To use serial port 1 and serial port 2, external power must be applied to VIOSEL (OEM
J4 pin 46) to set the IO voltage level. Connecting to camera interface boards and cameras sets this