EAN-FLIR Cameras
© SightLine Applications, Inc.
18
7.2
Boson Cameras - FPC/FFC
7.2.1
1500-OEM, 3000-OEM Cam0/Vin0, 4000-OEM
1.
Panel Plus main menu »
Configure
»
Serial Ports
.
2.
Set
Serial Port 2
to 921600 baud. Set the
Protocol
field to something other than
Port Not Used
.
Configure Port:
51,AC,14,3E,04,06,08,01,00,7F,64,05,A1,0F,00,00,00,00,00,00,4C,FE,DB
3.
Go to
File
»
Send Command
.
4.
Send:
51,AC,14,3D,04,8E,00,00,00,00,20,00,05,00,07,FF,FF,FF,FF,6E,83,AE,BB
•
51,AC = header
•
14 = length
•
3D = command pass through
•
04 = serial port 2 (change to 09 for serial port 6 on 4000-OEM)
•
8E ... AE = Boson command
•
BB = SLA checksum
7.2.2
3000-OEM Cam2 / Vin1
1.
Set
Serial Port 3
to 921600 baud. Set the
Protocol
field to something other than
Port Not Used
.
2.
Go to
File
»
Send Command
.
3.
Send:
51,AC,14,3D,06,8E,00,00,00,00,20,00,05,00,07,FF,FF,FF,FF,6E,83,AE,7F
•
51,AC = header
•
14 = length
•
3D = command pass through
•
06 = serial port 3
•
8E ... AE = Boson command
•
7F = SLA checksum
See the Panel Plus User Guide for instructions on creating Macros for these commands.