EAN-DRS-Cameras
© SightLine Applications, Inc.
3
4.2
3000-OEM DRS Camera Bench Setup
See
for the complete list of supported DRS cameras.
Interface and adapter boards:
•
: DRS camera and SLA-3000-FPC interface.
•
: DRS cameras and
interface. Provides serial and network interfaces. The
3000-OEM supplies power to the camera through the SLA-3000-FPC board.
•
: Provides serial and network interfaces. Adapter boards can be connected to one of
two available video input connectors (VIN1 or VIN0). See the 3000-OEM
drawing for more connection layout information.
VIN0 has camera channels 0 and 1 assigned. VIN1 has camera channels 2 and 3 assigned. If the
configuration includes an analog board with a digital adapter board the analog board must be
installed on VIN0.
•
(optional smaller IO board): Provides serial and network interfaces. This board
allows SLA-3000-HITACHI board to be connected directly to the OEM board.
Cable connections:
•
SLA-CAB-FPC04: Connects to the SLA-3000-FPC board and to the DRS cameras. Provides serial
communication and digital video to the camera. See
•
SLA-CAB-0403: Connects to J4 on SLA-3000-mIO board. Provides an RJ45 Ethernet connection.
•
SLA-PWR-C12V(110-250VAC input / 12VDC output): Connects to J5 on the SLA-3000-IO board. .
•
SLA-CAB-1504 / SLA-PWR-B12V (110-250VAC input / 12VDC output): Connects to J9 on the SLA-
3000-mIO board.
Power and network connectivity LEDs:
A green light on the 3000-IO or 3000-mIO board indicates that all boards are powered on. An amber
light on the 3000-OEM board verifies network connection.
Figure 3: 3000-OEM DRS Camera Bench Setup
SLA-3000-IO +
3000-OEM
Boards (stacked)
Network Switch or PC Direct
SLA-PWR-C12V
RJ45 Ethernet
Analog
Monitor
(optional)
Video Out
SLA-3000-FPC
on VIN1
SLA-CAB-FPC04
DRS Camera with
SLA-FPC-DRS
Network Switch or
PC Direct
SLA-CAB-0403 (J4)
SLA-3000-OEM +
SLA-3000-mIO+
SLA-3000-FPC
SLA-3000-FPC
on J4
SLA-3000-mIO
on J1
SLA-CAB-FPC04
Analog
Monitor
(optional)
SLA-PWR-B12V
DRS Cameras with
SLA-FPC-DRS
Serial (alternate)
Serial (0)
RJ45 Ethernet
SLA-CAB-1504 (J9)
IMPORTANT:
Disconnect
all input power to OEMs
and adapter boards
before connecting or
disconnecting cables.