3.16.2.
Example 2: Assess Link Stability 1000BaseT DUT in Slave mode, with Line and Offset Impairments
This task is performed using the
Port Config
,
Link Config
, and
Link Monitor
menus. Test Port 1,1 should be
connected to a DUT that supports 1000Base-T operation and supports Slave timing mode.
Hint: To force the DUT into
Slave
mode, the test port needs to be set for
Master
.
Menu
Task
Screen Shot
Port Select
Select the port to configure.
Click on
Port 1
in
Slot 1
on the
Slot
Port Select
menu.
Port Config
Configure the port to add the 100m
Line Impairment on all pairs and set
up +115 ppm timing offset.
Select the
Port Config
Tab.
115 ppm
under
Transmit
Timing Offset
Click
Apply Offset
Select
Impair All
under
100 Meter
Cat5e
Click
Apply Selected Port Settings
Link Config
Configure the test port speed, polarity
and duplex settings.
Select the
Link Config
Tab.
Select
1000BaseT
under
Link Speed
Select
Automatic
under
Link Duplex
Select
Automatic
under
Link Polarity
Click
Arm Configuration
Select
Master
under
Timing Mode
Click
Arm Configuration
Click
RE-LINK
Link Monitor
Verify link stability over 10 seconds
Select the
Link Monitor
Tab
Select
Gig. Remote
under
Sample
Select
100
under
Link Count
Select
100 msec
under
Count
Interval
Click
Measure
Expect:
LINKED
, Speed=
1000
,
MASTER
, Meas._Count=
100
Summary of Contents for PhyView PVA-3000
Page 22: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 22 ...
Page 70: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 70 ...
Page 108: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 108 ...
Page 124: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 124 ...