The
PSA-3000, PVA-3000, PSL-3000, PSL-3224
,
PSL-3024
Analyzers and Programmable Loads are shipped with
the following items:
PSA-3000/PSL-3000 chassis with one PSA-3000 controller blade, one or more test blades, and blank faceplates
to cover any unused slots (
Note: PSL-3024 uses a single faceplate for all test ports
)
One or more test blades up to 12 maximum (PSA-3x02, PVA-3102, or PSL-3x02)
PSA/PVA/PSL Software Installation CD
AC power cord
CAT5e Ethernet cables, crossover and standard
Console cable (Either USB A-B or RS232 Straight-through cable with DB9M to DB9F connections.)
Installation and Technical Reference Manuals (hard copy and on CD)
Two High-Quality, 5 ft. color-coded Test Leads per PVA-3102 test blade (
PVA-3000 only
)
The
PSA-3248
,
PSA-3048
RackPack PowerSync Analyzer is shipped with the following items:
(2) PSA-3000 chassis’ with 24 PowerSync Analyzer test ports per chassis, each chassis with single faceplate
covering all 24 test ports
PSA/PVA/PSL Software Installation CD
(2) AC power cords
(2) CAT5e Ethernet cables, straight-through
Console cable (Either USB A-B or RS232 Straight-through cable with DB9M to DB9F connections.)
Installation and Technical Reference Manuals (hard copy and on CD)
3.4.
Safety Precautions
TO PREVENT ELECTRIC SHOCK, DO NOT REMOVE THE COVER OF THE PSA. NO USER SERVICEABLE
PARTS ARE INSIDE. SERVICE SHOULD BE REFERRED TO QUALIFIED PERSONNEL.
THE PSA SHOULD BE POWERED DOWN AND DISCONNECTED FROM AC LINE VOLTAGES WHEN ANY
OF THE CARD SLOTS ARE UNPOPULATED OR UNCOVERED BY A BLANK FACEPLATE, AND WHEN
INSTALLING OR REMOVING CARDS OR FACEPLATES.
THE REMOVEABLE TEST CARDS MAY EXCEED SAFE HANDLING TEMPERATURES WHEN
OPERATING UNDER HEAVY CURRENT LOADS. CARDS SHOULD ALWAYS BE ALLOWED TO COOL
BEFORE REMOVAL FROM THE CHASSIS.
THE PSA IS FOR CONNECTION ONLY TO THE INTERNAL BUILDING ETHERNET NETWORK. IT IS NOT
FOR CONNECTION TO THE TELECOMMUNICATIONS NETWORK. THE PSA IS FOR INDOOR USE
ONLY.
THE PSA SHOULD BE POWERED VIA THE SUPPLIED AC POWER CORD, WHICH INCLUDES AN
EARTHING CONDUCTOR. THE GROUND TERMINAL OF THE PLUG SHOULD NOT BE MODIFIED,
SINCE THIS COULD RESULT IN A PRODUCT THAT IS NOT PROPERLY EARTHED. WHEN PLACING
THE EQUIPMENT IN ITS FINAL CONFIGURATION, THE EQUIPMENT SHOULD BE PLACED SUCH THAT
IT IS EASY TO ACCESS THE POWER CORD; THIS WILL ALLOW THE CORD TO BE PULLED OUT OF
THE UNIT IN THE EVENT THAT IT IS NECESSARY TO REMOVE POWER.
THERE ARE VENTILATION HOLES ON THE TOP AND BOTTOM COVERS, AND FAN VENT HOLES ON
THE BACK OF THE PSA-3000, PSA-3248, PSA-3048, PSL-3000, PSL-3224 AND PSL-3024 CHASSIS’. THERE
ARE VENTILATION HOLES ON THE SIDE AND FAN VENT HOLES IN THE BACK OF THE PSA-3402.
THERE ARE VENTILATION HOLES ON THE SIDE AND FAN VENT HOLES IN THE TOP OF THE PSA-
3002. THESE OPENINGS SHOULD NEVER BE BLOCKED OR OTHERWISE OBSTRUCTED DURING
INSTRUMENT OPERATION.
WARNING!
THE PSA-3002 and PVA-3002 SHOULD ONLY BE OPERATED WITH THE POWER
SUPPLY THAT WAS PROVIDED WITH THAT PRODUCT.