SAFETY
1.
Apply
power
only
after
reviewing
wiring
diagrams
printed
on
the
back
of
this
card
&
in
Instruction
Manual,
Ch.
2
2.
Apply
gas
flow
only
after
checking
plumbing
connections
for
leaks
3.
NEVER
TEST
FOR
LEAKS
WITH
LIQUID
LEAK
DETECTOR.
If
liquid
seeps
into
the
electronics
or
the
hidden
sensor
compartment,
the
instrument
may
be
damaged.
Instead,
use
a
pressure
‐
decay
test
(if
liquid
MUST
be
used
at
all,
limit
it
to
the
fittings
and
keep
it
off
the
body
of
the
instrument).
INSTALLATION
1.
Consult
the
instrument’s
Data
Label
(on
the
rear
of
the
instrument)
for
ALL
proper
operating
parameters.
If
the
information
on
the
Data
Label
does
not
match
your
process
conditions,
contact
your
Representative
or
Sierra
Instruments
Customer
Service.
2.
Install
a
10
micron
in
‐
line
filter
upstream
of
your
instrument.
If
the
gas
contains
any
moisture,
use
an
appropriate
dryer
or
desiccant.
Particles
larger
than
10
micron
and
moisture
may
damage
your
instrument.
3.
Mount
according
to
Data
Label
orientation.
Horizontal
flow
is
preferable
and
factory
default
UNLESS
the
factory
calibration
was
performed
specifically
for
vertical
flow
upward
or
downward,
as
listed.
Orientation
is
listed
on
the
Data
Label
and
on
the
Calibration
Certificate.
4.
DO
NOT
APPLY
POWER
TO
THE
OUTPUT
LOOP
.
This
is
NOT
a
loop
‐
powered
device.
5.
Apply
power
only
after
reviewing
wiring
diagrams
printed
on
the
back
of
this
card
&
in
Instruction
Manual,
Ch.
2
Power
is
applied
via
the
HD
DB15
connector.
The
CAT
‐
5
RJ45
connector
is
for
the
Sierra
Remote
Pilot
Module
or
provided
‘CRN’
cable.
DO
NOT
use
the
CAT5
RJ45
port
for
Ethernet—damage
to
your
computer
system
or
the
instrument
may
occur.
OPERATION
1.
Power
the
unit.
If
you
are
using
the
Sierra
provided
power
supply,
it
is
recommended
you
attach
the
D
‐
sub
connector
to
the
Smart
‐
Trak
2
before
plugging
the
adapter
into
the
wall.
The
unit
may
take
longer
to
start
than
normal
if
otherwise.
This
will
not
damage
the
unit.
The
green
LED
above
the
RJ45
connector
will
light
when
the
unit
powered.
2.
Our
Mass
Flow
Controllers
are
shipped
with
a
zero
setpoint
in
Automatic
valve
operation
mode.
For
safety
considerations,
it
is
recommended
you
confirm
this
prior
to
applying
gas
to
the
unit.
3.
Apply
the
gas
listed
on
the
Data
Label
to
the
inlet
at
the
recommended
pressure
(listed
on
the
Data
Label/Calibration
Certificate).
Your
Smart
‐
Trak
2
Meter
will
begin
to
measure
mass
flow.
This
will
be
displayed
on
the
user
software
or
display
module
that
you
have
hooked
up.
4.
Mass
Flow
Controllers
will
need
a
setpoint
input
in
order
to
control
flow.
Do
so
carefully!
You
can
digitally
input
a
setpoint
using
the
provided
User
Software
or
Pilot
Module,
or
control
directly
with
your
analog
setpoint
source.
NOTE:
You
can
change
the
setpoint
source
type
using
the
software
or
Pilot
Module.
The
unit
ships
in
the
configuration
initially
chosen
(or
default
if
not
specified).
This
information
is
also
listed
on
the
Data
Label
and
on