Innova-Sonic

®

 Model 205 Quick Start Instructions 

1

ˊ

Operation of Keyboard 

(Figure1-1)

 

0

 ~     

9

    are the menu codes to input information 

required for the flow measurement exercise. 

You can use 

Ż

   to delete or move back to the 

previous data. 

 

Ʒ

/  +

    ~ 

ͩ

/  -

   are to toggle up and down the 

menu. 

After all data is selected, press   

ENT

   to confirm. 

    MENU   

 is used to select a menu using two-digit 

numbers for each menu.    For example, to enter pipe 

outside diameter, select 

    MENU   

   

1

       

1

    to enter into the window (

Ā

MENU11

ā

is the address 

code of the outer pipe diameter). 

2

ˊ

Transducer Connection

˄

Figure2-1

˅DŽ

 

 

(

11

)GND--PE 

˄

18

 Ground 

˅

-

˄

DN

˅

screen wire      

˄

21

 Ground 

˅

-

˄

UP

˅

screen wire 

(

12

)L-- AC     

˄

19

 

Conductor

˅

- (

DN

) red wire-core       

˄

22

 

Conductor

˅

- (

UP

) red wire-core 

(

13

)N --AC 

˄

20

 

Shield Layer

˅

(DN

) black wire-core   

˄

23

 

Shield Layer

˅

- (

UP

) black wire-core 

Note

˖

The upstream transducer cable is coded red and the downstream is blue. 

Figure

˄

2-1

˅

Connection of the flow meter’s transducers 

3

ˊ

Measurement Site Selection 

˄

Figure2-2

˅

                                                                             

  Figure2-2 Installation at the 3 o’clock and 9 o’clock positions 

 

Figure1-1 Keyboard 

 