background image

California Prop 65 Warning: This product can expose you
to  chemicals  including  glass  wool  fiber  and  carbon
monoxide  which  the  State  of  California  has  determined
can cause cancer, birth defects, and other reproductive
h a r m .  

F o r  

m o r e  

i n f o r m a t i o n  

g o  

t o

www.P65Warnings.ca.gov 

SAFETY NOTICE

<

CAUTION:  HOT  WHILE  IN  OPERATION.  KEEP
CHILDREN, CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.

<

IF THIS HEATER IS NOT PROPERLY INSTALLED,
A HOUSE FIRE MAY RESULT.

<

CONTACT LOCAL BUILDING OFFICIALS ABOUT
RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.

<

FAILURE TO COMPLY WITH OWNERS' MANUAL
INSTRUCTIONS WILL VOID YOUR WARRANTY!

WARNING:  FOR  INSTALLATIONS  IN  MOBILE

HOMES, DO NOT INSTALL IN SLEEPING ROOM.

S2300 Wood Heater Manual

Installation and Operating

Instructions

Please read this entire manual before installation. Save these instructions.

GENERAL INFORMATION

Congratulations on your purchase of the Sierra Stove. We

are confident that your new stove will provide you with years

of safe, comfortable and efficient heating.

Your Sierra Stove is a free-standing/mobile home approved

wood fueled heating appliance tested to the ICBO TL-130 &

Canadian test ULC S627. Safety testing is according to UL'

1482 and UM 84. HUD standards.

This manual describes the installation and operation of the

Sierra S2300 wood heaters.

EMISSION CERTIFICATION STATUS

The S2300 model meets the U.S. Environmental Protection

Agency's  emission  limits  New  Source  2020,,  ASTM

E3053-2017 and EPA Alternate Test Method (ATM) 125 for

cordwood. Under specific test conditions this heater has been

shown to deliver heat at rates ranging from 11,000 to 45,500

Btu/hr capable of heating approximately 2,100-2,600 square

feet. Actual heat output and space heated is determined by:

climate, home construction, species and moisture content of

wood.

This wood heater has a manufacturer-set minimum low

burn rate that must not be altered. It is against federal

regulations to alter this setting or otherwise operate this

wood heater in a manner inconsistent with operating

instructions in this manual

Please read this entire manual before you install and use

your new room heater. Failure to follow instructions may

result in property damage, bodily injury, or even death.

Save these instructions for future reference.

SAFETY NOTICE

If this appliance is not properly installed, a house fire may

result. For your safety, follow the installation instructions. 

Check with local building or fire officials about restrictions

and installation inspection requirements in your area.

Installation into mobile homes require outside combustion

air and special hearth attachments. For Mobile Homes,  a

Combustion Air Kit P/N 11069 is available from your

dealer. 

It is best to have a professional install your Sierra Stove. If

you prefer to install it yourself (see Installation

Instructions), be sure to obtain the proper permits. Have

the local building officials inspect the stove and chimney

pipe for safety and code compliance after the installation is 

complete.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE

SERVING ANOTHER APPLIANCE.

            

OVERALL DIMENSIONS

This  wood  heater  needs  periodic  inspection  and
repair  for  proper  operation.  It  is  against  federal
regulations to operate this wood heater in a manner
inconsistent  with  operating  instructions  in  this
manual.

PLEASE LEAVE THIS MANUAL WITH THE OWNER !!

Summary of Contents for S2300

Page 1: ...has been shown to deliver heat at rates ranging from 11 000 to 45 500 Btu hr capable of heating approximately 2 100 2 600 square feet Actual heat output and space heated is determined by climate home construction species and moisture content of wood This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or othe...

Page 2: ...ion such as an R value thermal resistance k factor thermal conductivity or C factor thermal conductance The easiest means of determining a proposed alternate floor protector that meets the requirements listed in this manual is to follow this procedure 1 Convert specification to R value i R value given no conversion needed ii k factor is given with a required thickness T in inches R 1 k x t iii C f...

Page 3: ...y and any other combustibles 3 feet away from your woodstove 4 Never burn garbage in your woodstove By garbage we mean plastics aluminum wrappers slick paper magazines or styrofoam of any kind Garbage fouls your chimney and the air 5 Use caution when loading fuel into stove after it is already burning vigorously Avoid resting fuel against the glass as this will cause dirty spots 6 Burn dry wood on...

Page 4: ...re 3 Carefully measure once more to make sure that both stove and pad are placed to meet proper clearances to combustibles Using a 5 16 metal drill bit drill one hole on each side of the pedestal flange for the anchor bolts to pass through Figure 3 Mark and drill the two anchor holes with the 1 4 Masonry drill bit Bolt down the stove using the two 1 4 x 3 lag bolts provided The 8 copper wire shoul...

Page 5: ... kit therefore it is not necessary to cut a hole in the floor or the hearth pad Follow the instructions included in your approved pipe kit for proper chimney pipe installation BLOWER INSTALLATION INSTRUCTIONS A room air circulation blower P N 11047 is available from your local dealer Install blower assembly per the installation instructions included with the kit CORDWOOD FUEL LOADS Cordwood Fuel G...

Page 6: ...firebox heat and coal bed for the large long burn load Kindling Made from small pieces diameter and 6 12 long A hatchet works well for splitting a small piece of cord wood length wise You ll need about 4 lbs of kindling to heat up the flue and start a small draft Starting Load Made up of 2 diameter pieces 12 16 long You ll need about 6 lbs of start up fuel to build the coal bed and warm up the sto...

Page 7: ...o allow the stove to burn for a longer period of time with the air control rod pulled all the way out It may also be necessary to use more kindling material in order to get a well established fire going As you use your stove you will become more familiar with your individual start up requirements 4 The best efficiency heat control and cleanest glass door is achieved through proper use of the draft...

Page 8: ...hese deposits from your stove pipe and chimney Creosote deposits are dangerous and are deemed a flue fire waiting to happen Visually check your chimney monthly If creosote deposits are more than 1 4 thick remove them MAINTENANCE The following tips on maintenance will help you keep the Sierra Stove performing in an attractive and efficient manner Glass In the event that you need to clean your glass...

Page 9: ...ierra Wood Stove notify your nearest dealer or contact Sierra Products Inc at www sierraproductsinc net customer support technical service Sierra Products Inc 63 Laxalt Dr Carson City NV 89706 775 241 2586 P N 140969 D S2300 WOOD STOVE MANUAL 9 ...

Reviews: