![Sierra Wireless AirPrime WP75 Series At Command Reference Download Page 158](http://html1.mh-extra.com/html/sierra-wireless/airprime-wp75-series/airprime-wp75-series_at-command-reference_1266754158.webp)
AirPrime WP8548 / WP75xx / WP76xx / WP77xx AT Command Reference
158
Proprietary and Confidential - Contents subject to change
4118047
Command reference
Table 5-2: Diagnostic Command Details
Command
Description
!BCFWUPDATESTATUS
Report status of most recent firmware update attempt
Return the status of the most recent firmware update attempt made since the last cold
restart.
Password required:
No
Usage:
•
Execution:
AT!BCFWUPDATESTATUS
Response:
!BCFWUPDATESTATUS: <result>
or
!BCFWUPDATESTATUS: <result>
Failed IMG TYPE <type>, DATA <data>, PART <part>
OK
Purpose:
Return the status of the most recent firmware update attempt. The
second response format appears only if <result> = “FAILED”.
Parameters:
<result> (Status of last firmware update attempt)
•
ASCII string:
•
“UNKNOWN”—Status of last attempt is unknown.
•
“SUCCESS” —Last update was successful.
•
“FAILED”—Last update failed.
<type> (Firmware image type that failed to update)
•
ASCII string
<data> (Reference data for failed image)
•
Location of the reference data as an offset in the CWE image
•
Valid range: 0–(2
32
-1)
<part> (Partition associated with the failed image)
•
ASCII string