4117047
Rev 2.2
December 18, 2015
20
Product Technical Specification
Detailed Interface Specifications
The figure below shows the power supply voltage drop shapes during GSM 2G transmission.
Figure 5.
Power Supply Voltage Drops Shapes During Burst Transmission
2.4. Current DC Power Consumption
The following table lists the current consumption of the AirPrime HL8518, HL8528 and HL8529
modules at different conditions.
Note:
The following data is under the setup recommended in section 3.5 Power Supply Design.
The USB is disconnected for the lowest current consumption.
Typical values are measured at ambient temperature, and maximum values are measured over the
entire operating temperature range. (The measurements are done with a CMU200 and with a 50
Ω
load.) For a description of input voltage requirements, see section 2.1 Power Supply.
Table 8.
Current Consumption (at nominal voltage, 3.7V)
Parameters
Typical
Maximum
Off mode
50 µA
Sleep mode - GSM DRX2
(registered to the network)
GSM900
1.5 mA
3.15 mA
DCS1800
1.5 mA
3.15 mA
GSM850
1.6 mA
3.4 mA
PCS1900
1.6 mA
3.4 mA
Sleep mode - GSM DRX9
(registered to the network)
GSM900
1.15 mA
2.7 mA
DCS1800
1.0 mA
2.7 mA
GSM850
1.3 mA
2.9 mA
PCS1900
1.25 mA
2.95 mA
Sleep mode - WCDMA DRX6
(registered to the network)
Band 1
1.75 mA
3.45 mA
Band 2
2 mA
3.75 mA
Band 5
2 mA
3.8 mA
Band 8
1.75 mA
3.5 mA