Sierra Wireless Airlink Raven XE H2225E Router 

 

Description 

The target of the Airlink Raven XE is the Alarming Module.  Its purpose is to Send and Receive SMS 
messages.  Essentially, it is going to be utilized as an SMS gateway.  As an example, Ignition picks up 
information from a PLC that the water temperature is too hot.  Ignition send an SMS message via the 
Raven XE to contacts assigned to that alarm.  It is received by a contact, which is then acknowledged via 
SMS by the contact.  This SMS message is sent back and received by Ignition via the Raven XE. 
 

Raven XE and Network Security 

The security settings covered here are basic steps to secure the Raven XE.  Inductive Automation is not 
responsible for the security of your Raven XE.  You should take the time to configure and test the 
current and other security measures as appropriate to your network. 
 
Inductive Automation tested this router as a device that sits inside a network.  Therefore, it needs to be 
configured to act simply as another device on the network, not as a router or DHCP Server etc.  Its sole 
purpose is to handle SMS traffic.  The setup steps below cover these.  If you wish to utilize its other 
features, bear in mind that you will need to ensure it works properly on your network and is secure. 
  

Configuration and ACEManager 

To access and change the modem’s configuration information, you will be accessing what is called the 
ACEManager.  This can be accessed via Ethernet, USB or Serial.  This document will only cover Ethernet 
access.  The recommended browser to use is IE or Firefox.  ACEManager run poorly under Safari and 
Chrome. 
 

Setup Steps 

 
The sections below should be followed in the order given to setup the Raven XE H2225E.  Note that any 
change that is made usually requires a reboot of the modem, which can be done through the 
ACEManager.  Follow these instructions and reboot at the end.  
 

Default Ethernet Connection 

First connect the Raven XE directly to your computer and follow the manual’s instructions to 
connect to it. 
 

Default Ethernet settings for access is: 

Device IP Address: 192.168.13.31 
Port: 9191 
Username: user 
Password: 12345 

 

Summary of Contents for Airlink Raven XE H2225E

Page 1: ...needs to be configured to act simply as another device on the network not as a router or DHCP Server etc Its sole purpose is to handle SMS traffic The setup steps below cover these If you wish to util...

Page 2: ...connect the Ethernet cable from your laptop to the router 2 Set your computer to DHCP 3 Double click on the file to execute the firmware upgrade program 4 You will be entering the IP address of 192 16...

Page 3: ...o the LAN Host Port Routing Tab The router must be set to NOT act as the gateway on the network Primary Gateway Disabled Failure to make the above setting may cause devices on the network to cease fun...

Page 4: ...Over The Air By default the ACE Manager can be accessed over the air If you load the Inductive Automation default configuration it is disabled This will add security to the device to prevent access fr...

Page 5: ...omation default configuration SSH is used in preference to Telnet To SSH into the router use Putty or some other SSH Client See Ethernet section for IP and login credentials The SSH Port number to use...

Page 6: ...d Go to the Services SMS tab The following changes are made SMS Send Enabled is Enabled Non Trusted Read Security is Allow Access Non Trusted Write Security is Allow Access There are other security fe...

Page 7: ...ort Filtering and Outbound Ports To prevent outbound http and https traffic over the air from the Raven XE I have utilized Port Filtering Under Security Port Filtering Outbound enter ports 80 and 443...

Page 8: ...d all LAN connected devices You would use the Public IP Address that someone would be accessing the Raven XE over the air Per the manual Trusted IPs Outbound restrict access to external networks to IP...

Page 9: ...SIM card with only text and minutes we were unable to access the ACEManager over the air and when the Raven XE was acting as the Primary Gateway we were unable to get http traffic out Troubleshooting...

Reviews: