Sienna ES60GFDBL Use And Care Manual Download Page 12

12

ADJUSTMENTS

Always  disconnect  the  appliance  from  the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our  burners  do  not  require  primary  air
adjustment.
a) Data Label

The  Data  Label  is  located  on  the  underside  of  the
hotplate. A  duplicate  Data  Label  is  supplied  to
adhere  in  an  accessible  area  next  to  the  hotplate.
This  hotplate  is  suitable  for  Natural  Gas  and
Universal  LP  Gas;  ensure  that  the  available  gas
supply matches the Data Label.

b) Before Leaving

Check that there are no gas leaks, but do not use a
naked  flame  to  detect  gas  leaks.  Ignite  all  burners
both individually and concurrently to ensure correct
operation  of  gas  valves,  burners,  ignition  and  if
fitted,  flame  failure  valves.Turn  gas  taps  to  low
flame  position  and  observe  stability  of  the  flame.
When satisfied with the hotplate, please instruct the
user on the correct method of operation. In case the
appliance  fails  to  operate  correctly  after  all  checks
have  been  carried  out,  refer  to  the  authorised

service provider in your area.

7) TAPS

Our  taps  are  suitable  for  all  gas,  they  are  male
conical type.

“Reduced rate” adjustment 

- Switch on the burner and turn the relative knob to the

“Reduced rate” position (small flame fig.1- pag. 3).

- Remove knob  “M” (fig. 9 and 9/A) of the tap, which

is  simply  pressed  on  to  its  rod.  The  by-pass  for
minimal rate regulation can be: beside the tap (fig.
9)  or  inside  the  shaft.  In  any  case,  to  access  to
regulation, it can be done through the insertion of
a small screwdriver ‘’D’’ beside the tap (fig. 9) or in
the  hole  ‘’C’’  inside  the  shaft  of  ta p  
(fig 9/A). Turn the throttle screw to the right or left
until  the  burner  flame  has  been  adequately
regulated to the “Reduced rate” position.

The  flame  should  not  be  too  low:  the  lowest  small

flame  should  be    continuous  and  steady.  Re-
assemble the several components.

It  is  understood  that  only  burners  operating
with  Natural  gas  should  be  subjected  to  the
above mentioned adjustments. 

FIG. 9

FIG. 9/A

TAPS LUBRIFICATION

Should a tap being blocked, do not

force and ask for Technical

Assistance. 

FIG. C

Summary of Contents for ES60GFDBL

Page 1: ...ES60GFDBL ES700GFDBL ES90WGFDBL COD 04067IE 17 05 2016 REV00 ...

Page 2: ...T IN HOTPLATE We ask that you carefully read the instructions within this booklet to enable you to abtain quality results from the outset The appliance must be installed only by an authorised person in compliance with the instructions provided The manufacturer declines all responsability for improper installation which may harm persons and animals and damage property The appliance must be used for...

Page 3: ...Pan stands support 1F 8 Burner n 2 control knob 9 Burner n 5 control knob 10 Burner n 1 control knob 11 Burner n 3 control knob 12 Burner n 4 control knob Attention this appliance has been manufactured for domestic use only Do not modify this appliance DESCRIPTION OF HOTPLATE To use the WOK pan support on ultra rapid gas burner only if present Put it on the ultra rapid pan support and make sure of...

Page 4: ...ut situation Never leave the appliance unattended when the burners are being used Make sure there are no children in the near vicinity Particularly make sure that the pan handles are correctly positioned and keep a check on foods requiring oil and grease to cook since these products can easily catch fire The appliance must not be used by people including children with impaired mental or physical c...

Page 5: ...pliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervised or instruction concerning use of the appliance by a responsible person for their safely Young children should be supervised to ensure that they do not play with the appliance Abnormal Operation Any of the follo...

Page 6: ...e Customer Care Department Abnormal operations Any of the following are considered to be anormal operation and may require servicing Yellow tipping of the hob burner flame Sooting up of cooking utensils Burners not igniting properly Burners failing to remain alight Burner extinguished by cupboard doors Gas valves which are difficult to turn CAUTION In case of hotplate glass breakage shut immediate...

Page 7: ...ner head slots T fig 3 have not become clogged by foreign bodies Check that the enamelled burner cap A B C fig 3 3 A has been correctly positioned on the burner head It must be steady The pan support must be placed in the appropriate centering pins verifying the perfect stability Do not force the taps if they are difficult to open or close Contact an Authorised Service Centre for repairs Don t use...

Page 8: ...e the packaging materials cardboard bags polystyrene foam nails etc within children s reach since they could become potential sources of danger The measurements of the opening made in the top of the modular cabinet and into which the hotplate will be installed are indicated in either fig 4 Always comply with the measurements given for the hole into which the appliance will be recessed see fig 4 4 ...

Page 9: ...g hooks G fig 6 When the appliance is installed so that the base can be touched we recommend fitting a protecting shield This shield must be at least 70 mm below the base of the bench top fig 4 Timber or other suitable material may be used provided it is capable of withstanding the appliance temperatures Ensure that the supply connection point is accessible with the appliance installed To facilita...

Page 10: ... leaks The gas supply connection point must be accessible with the appliance installed Warning ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of an underbench oven Natural Gas Natural Gas installations require the connection of a gas regulator at the appliance This regulator is supplied with the appliance on purchase Assemble the regulator noting t...

Page 11: ...onnected to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure C taking care of respecting the following correspondences Letter L live brown wire Letter N neutral blue wire Earth symbol green yellow wire The power supply cable must be positioned so that no part of it is able to reach an overtemperature of ...

Page 12: ...case the appliance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all gas they are male conical type Reduced rate adjustment Switch on the burner and turn the relative knob to the Reduced rate position small flame fig 1 pag 3 Remove knob M fig 9 and 9 A of the tap which is simply pressed on to...

Page 13: ...l included in the gas conversion kit 9 NATURAL GAS TO UNIVERSAL LP GAS CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models 1 Remove each burner cap and burner skirt 2 Remove the Natural Gas main injector with a 7 mm VF tube spanner and replace with the appropriate size Universal LP Gas main injector for each burner The following injector sizes are required for Universal LP Ga...

Page 14: ...his label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or at disposal to the authorised Customer Care Department For the sake of convenience the nominal rate chart also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas BURNER ARRANGEMENT ON TH...

Page 15: ...onductors fig 11 and comply with the recommendations given in paragraph 6 WARNING MAINTENANCE MUST ONLY BE PERFORMED BY AUTHORIZED PERSONS If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n order to avoid a hazard WARNING In the envelope you will find the duplicate parts of the rating plate which must be applied in the cab...

Page 16: ...e Centre whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only available from our After Sales Service Centres and a qualified retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packing label The above informations giv...

Reviews: