Mounting / Installing / Connecting
4.7 Limiting the charging current
VersiCharge AC Wallbox IEC
32
Operating Instructions, 03/2021, A5E50366109-AA
4.7
Limiting the charging current
The rated current of the respective model (see nameplate) is set for the VersiCharge charging
unit. This can be limited further using the selector switch placed on the charging controller.
See the figure below.
Note
Work can only be performed by an qualified electrician
Only a qualified electrician can limit the maximum charging current to the infeed power
using the rotary switch. The design and protection of the supplying current circuit must be
adapted to the set charging current. Observe the local regulations / connection conditions.
Setting the current of the VersiCharge unit*
Figure 4-6
Charging current
1.
Open the cover.
2.
Remove the protective cover.
3.
Set the desired charging current by turning the selector switch to the corresponding value.
4.
Close and secure the cover of the charging unit. Check that the seal is sitting correctly.
Note
In positions 5-9, the current is increased to no higher than the maximum value for which the
hardware is designed.
Summary of Contents for VersiCharge
Page 1: ......