VersiCharge™ AC series – Technical data
Features and functions
Charging mode
Level 2
Vehicle connection
J1772 plug with 20 ft cable, 40/48 A / integrated cable management
AC power output
Single phase up to 9.6 kW (40A) - requires a 50A breaker, or 11.5kw (48A) - requires a 60A breaker
Mounting options
Wall and post mounting, see accessories
Touch Button
Time delay, return to max power level, reset ground fault
Charging status LEDs
Power, time delay, charging state, reduced power level, authentication, cold start
Communication status LEDs
Connected / not connected during operation, signal strength during commissioning
Parent/child Network:
Connects up to 9 child units by Wi-Fi (100 ft line of sight)
Load management
via OCPP or via Modbus
Communication
Interfaces
Ethernet, Wi-Fi, Modbus RS-485, Modbus TCP/IP, for parent units additionally LTE, WCDMA
User authentication
RFID (local Whitelist, MiFare)
Configuration
via Siemens mobile app or the PC Configuration tool
Back-end protocol
OCPP 1.6, upgrade-able to OCPP 2.0.1
Software upgrade
over the air (OTA)
Electrical design
Power supply voltage
Single phase: 208 V / 240 V AC, 60 Hz
Rated current settings (A)
12, 16, 24, 32, 40, 48
Cross wire section
Single phase: 8 AWG / 6 AWG (90° C rated wire)
Network type
Single phase / split phase
Energy metering
Embedded metering, +/- 1% accuracy
Ground fault protection
20 mA
Over voltage protection
Under voltage: 167 V (min. 80 V) / over voltage: 267 V (max. 275 V)
Over current protection
C10% above configured threshold, min. +2A, 5 seconds
Operating altitude
9,840 ft
General design
Environmental rating
Indoor and Outdoor, NEMA 4, IK 8
Dimensions (HxWxD)
16.10 in x 7.09 in x 3.78 in
Weight
17 lbs
Ambient conditions
Operating temperature: -31°F - +122°F, Storage Temp.: -40°F to +140°F, 98% non condensing
Colors
Silver Metallic (Pantone 10077), Black holster
Certificates and standards
cUL listed
according to UL 1998, UL 991, UL2594/CSA C22.2 No.280/NMX-J-677-ANCE, UL 2231-1/CSA C22.2 No.281.1/
NMX-J-668-1, UL 2231-2/CSA C22.2 No.281.2/NMX-J-668/2-ANCE, UL 2251/CSA C22.2
No.282/NMX-J-678-ANCE
EMC
FCC Part 15.247, FCC Part 15B, FCC Part 15C
Max.
current Model number
Wi-Fi and
Ethernet
Modbus
RTU / TCP
RFID
identification
Embedded
metering
LTE
WCDMA
Installed
SimCard
Residential
version
Smart
40 A
8EM1312-4CF18-0FA3
–
–
–
–
48 A
8EM1312-5CF18-0FA3
Commercial
versions
Child
40 A
8EM1310-4CF14-0GA0
–
–
48 A
8EM1310-5CF14-0GA0
Parent
40 A
8EM1310-4CF14-1GA1
–
40 A
8EM1310-4CF14-1GA2
48 A
8EM1310-5CF14-1GA1
–
48 A
8EM1310-5CF14-1GA2
Back-end protocol: OCPP 1.6, upgradeable to OCPP 2.0.1
Data plans for chargers:
Siemens offers chargers with data plans for customer convenience. See table below for data plans.
Description
Catalog Number
AT&T 1 year data plan, 2GB capped monthly bandwidth (supports ONE Parent charger).
P3R77992000784
AT&T 1 year data plan, 5GB capped monthly bandwidth (supports ONE parent charger and up to 9
commercial child chargers). This is a yearly fee that Siemens will bill direct after year one.
P3R77992000800
Extended Warranty per Level 2 charger - 1 additional year, No In/Out services
US2:VCEXWAR1YR
Extended Warranty per Level 2 charger - 2 additional years, No In/Out services
US2:VCEWAR2YR
48