3. Remove barrier by removing the two securing screws.
4. Connect to the Multi-use connector by gently pressing the connector on to it.
5. Press the Remote Control cable through the rubberized gland at the back of the unit without the connector
attached. This gland will self-seal.
NOTE:
Do not press the cable with the connector attached through this gland, that will cause the loss
of the NEMA 4 rating.
6. Attach the Remote Control cable connector and attach the two cable connectors.
7. Gently tuck the cables into the back of the unit and close the case.
NOTE:
When the external contact is closed, no charging will occur.
NOTE:
The status output is a switch that indicates charging status. When the contacts are closed, the
unit is in charging state.
3.4 SIM Card Installation – If Not Factory-installed (Commercial Parent Units Only)
Figure 11. Sim card installation
This hardware uses a micro SIM card, but with an adapter will allow nano SIM cards.
The SIM card should NOT require a PIN. Locked SIM cards are not supported by VersiCharge hardware.
The following carriers are supported : USA: AT&T, T-Mobile, and Canada: Rogers, Telus. Data plans should have a minimum
consumption of 250 MB per month per charger.
Explosion hazard.
This equipment has arcing or sparking parts that should not be exposed to
flammable vapors. This equipment should be installed at least 18 inches above the floor or ground
level. Use extreme caution and follow instructions carefully.
22
VersiCharge™ AC Electric vehicle charging station