Outlet
Installation
STEP 1
Standard Mounting -
Recommended (Figures
1 and 2)
1. Find the stud.
2. Place the mounting bracket no more than 12” above the outlet, and use it as a guide to mark the location of the top
center hole.
3. Drill a pilot hole.
4. Mount the bracket using the top hole and the lag screws, DO NOT tighten all the way.
5. Level the bracket
6. Drill a pilot hole for the center-bottom hole.
7. Secure with lag screws.
8. Tighten top and bottom screws using Allen wrench.
For concrete cinder block walls, install appropriate anchors. If using an existing outlet, ensure that power cord will reach to
the outlet. Using a 7/16” socket, attach mounting bracket to wall in compliance with all National Electrical Code® (NEC) and
local jurisdiction requirements, using the (2) ¼” x 2” lag screws provided.
For Siemens Post installation see the post instruction manual at:
STEP 1A
Alternate Mounting
- Wallboard
Installation (Figure 3)
NOTE:
Anchor Rating: 5 anchors must be rated as 61 lb. anchors rated for 1/2” dry wall .
The VersiCharge can be mounted using 5 - #12 x 1-½ LG Phillips head 0.375 head minimum with 5 - #12 wall anchors.
1. Locate the mounting bracket not more than 12” above a 240 V outlet or if hardwiring, the wiring will come through the
bottom of the charger.
2. Level the mounting bracket and drill 4 holes, one in each corner of the bracket.
3. Place anchors into the wallboard until they are flush with the wall.
4. Place the mounting bracket over the holes (hinges facing upward, flat side of the bracket against the wall) with the
anchors and screw the mounting to the wall securely.
5. Add a 5th hole for mounting the holster once the unit is mounted on the wall. Place the holster on the wall and mark
the correct position for the hole. Refer to Step 12.
STEP 2
Install/Mount Charger
(Figure 4)
NOTE:
For installation, the mounting-bracket hinges will be pointing to the ceiling, and the flat side of the bracket will be
against the wall.
1. Slide the VersiCharge on to the hinges.
2. Rotate to the right until the unit clicks and is closed.
3. Secure the enclosure with the locking mechanism and plug the VersiCharge into the 240 V outlet. If hardwiring the unit,
aa
see Hardwire Installation in Step 4.
STEP 3
Set Amp Switch
(Figure 5)
DANGER
Hazardous voltage. Will cause death or serious injury.
Turn off power before working on this equipment. This indicates
a situation where the present voltage could cause injury or death.
Extreme caution is required when servicing or installing the
equipment referenced.
The VersiCharge comes set to the maximum of the model purchased (For example, a 40 A model will come with the amp
adjustment switch set to 4, and a 48 A unit amp adjustment switch will be set to 5.). Verify the required amp adjustment switch
setting based on the branch circuit protection (see the table below).
Amperage Settings
Switch Position
witch
Position
Amps
0
12
1
16
2
24
3
32
4
40
5
48
NOTE:
Do not set switch above the 40A unless hardwired via dedicated 60 A branch protection.
Settings: 0 - 4 amperage adjustment settings are used for the 40 amp charger (note: the #5 position
will cause a bad switch fault for the 40 amp charger) and 0 - 5 amperage adjustment settings are used
for the 48 amp charger. Setting the amperage adjustment higher than 5 will result in a fault.
10
VersiCharge™ AC Electric vehicle charging station
Summary of Contents for VersiCharge AC
Page 1: ...QUICK START INSTALLATION GUIDE VersiCharge AC Electric vehicle charging station ...
Page 21: ...Notes 22 VersiCharge AC Electric vehicle charging station ...
Page 22: ...Notes 23 VersiCharge AC Electric vehicle charging station ...
Page 23: ...Notes 24 VersiCharge AC Electric vehicle charging station ...