2 Technical Requirements for system with PC Mux
2.1 System Software
•
Windows
NT4.0
This requirement only refers to PC Mux software which we provide for testing purposes. It has been
developed for Windows NT 4.0. Of course the multiplexer protocol can be implemented in any OS.
2.2 PC Multiplexer Simulation Software
In order to use the PC Mux, you get a *.zip file, which includes
files to install the PC Multiplexer Simula-
tion Program on your PC.
The PC Mux is a Windows NT program, which enables the usage of the external multiplexer on a PC.
This program is a suitable means to demonstrate and make use of the functionality of the multiplexer
during the development phase. Only the binary versions of the PC Mux files will be provided.
Provided files:
When you extract the *.zip file the following files will be extracted onto your PC:
•
chopper.exe
•
controller.exe
•
log.exe
•
muxappl.exe
•
muxport.exe
•
muxtester.exe
•
pcmux.dll
•
process.exe
•
send.exe
•
sharecnt.dll
•
simcom.sys
•
simcominstall.xls
•
simulation.exe
•
simulation.ini
•
trace.exe
The file pcmux.dll includes all *.c and *.h files, which form the multiplexer protocol. They must be inte-
grated in the module software as well as on the PC side. Refer to chapter 6.1 for detailed information
about the purpose of each file.
2.3 Hardware
•
Minimum Pentium III, 133 Mhz
•
e.g. DSB35 or TC35T (during development or testing phase)
•
TC35 module with baud rate set to 57600 bps
2.3.1 Using virtual COM Ports
•
1 RS232 interface
•
1 RS232 cable